BK1120 | Beckhoff EtherCAT Bus Coupler, 100BASE-TX, Supports Up to 64 Terminals
BK1120 | Beckhoff EtherCAT Bus Coupler, 100BASE-TX, Supports Up to 64 Terminals
BK1120 | Beckhoff EtherCAT Bus Coupler, 100BASE-TX, Supports Up to 64 Terminals
    BK1120 | Beckhoff EtherCAT Bus Coupler, 100BASE-TX, Supports Up to 64 Terminals
BK1120 | Beckhoff EtherCAT Bus Coupler, 100BASE-TX, Supports Up to 64 Terminals

BK1120 | Beckhoff EtherCAT Bus Coupler, 100BASE-TX, Supports Up to 64 Terminals

Part #: BK1120 Manufactured by: Allen-Bradley
Regular price
$382.00
Sale price
$382.00
Regular price
4 in Stock
Condition: New – Open box
Shipping calculated at checkout.
Product Overview
The BK1120 EtherCAT Coupler serves as the intermediary link between the EtherCAT protocol at the fieldbus level and the B...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: BK1120
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: BK1120

Description / Specifications

Description 

The Beckhoff BK1120 EtherCAT Bus Coupler links the EtherCAT fieldbus system with Beckhoff Bus Terminals, converting Ethernet 100BASE-TX telegrams to the internal terminal bus. It supports automatic process image assignment and enables modular expansion for flexible industrial I/O architectures.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Part Number BK1120
Manufacturer Beckhoff
Category PLCs/Machine Control
Subcategory PLC Module/Rack
Number of Bus Terminals 64 (255 with K-Bus extension)
Max. Fieldbus Data 1024 bytes input / 1024 bytes output
Configuration KS2000 or EtherCAT (ADS)
Data Transfer Rate 100 Mbit/s
Bus Interface 2 × RJ45
Medium Ethernet/EtherCAT Cat.5 cable
Power Supply 24 VDC (-15% / +20%)
Input Current 70 mA + K-Bus current/4 (max. 500 mA)
Starting Current Approx. 2.5× continuous current
Recommended Fuse ≤ 10 A
K-Bus Current Supply 1750 mA
Power Contacts Max. 24 VDC, 10 A
Electrical Isolation 500 V (contacts/supply/Ethernet)
Max. Station Distance 100 m (100BASE-TX)
Data Transfer Time 0.01 ms (10 modules, 32-bit I/O, no K-Bus runtime)
Operating Temp. –25…+60 °C
Storage Temp. –40…+85 °C
Relative Humidity 95% (non-condensing)
Vibration/Shock EN 60068-2-6 / EN 60068-2-27
EMC EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Weight Approx. 150 g
Approvals CE, UL, ATEX, IECEx

 

 

Information About BK1120

The Beckhoff BK1120 EtherCAT Bus Coupler provides seamless interfacing between the EtherCAT fieldbus and the Bus Terminal system by translating Ethernet 100BASE-TX telegrams into the internal, fieldbus-independent terminal bus. A standard station supports up to 64 Bus Terminals plus an end terminal, while the K-Bus extension allows installations to scale up to 255 terminals. The coupler integrates two RJ45 interfaces—one for upstream communication and the other for cascading downstream EtherCAT devices—enhancing network versatility. With direct 24 VDC system and field supply inputs, the BK1120 distributes communication and load power efficiently across connected terminals. Its robust isolation, high-speed transfer performance, and compliance with industrial standards make it a reliable backbone component for modular EtherCAT architectures.

Key Features:

  • High-speed EtherCAT interface: Converts Ethernet 100BASE-TX telegrams to the internal terminal bus for fast and deterministic communication.
  • Scalable system architecture: Supports 64 Bus Terminals natively and up to 255 terminals with K-Bus expansion, enabling large I/O stations.
  • Dual RJ45 ports: Allows network daisy-chaining and simplified EtherCAT topology design in complex installations.
  • Robust electrical design: 500 V isolation and 10 A power contacts ensure reliable operation in industrial environments.
  • Automatic process image assignment: Reduces configuration time and ensures seamless integration with EtherCAT masters.
  • Wide environmental tolerance: Operates from –25°C to +60°C with full industrial EMC compliance for harsh applications.
  • Flexible configuration options: Programmable via KS2000 or EtherCAT ADS for versatile system integration.

The BK1120 delivers the reliability and precision required for scalable, high-speed EtherCAT-based automation systems.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Beckhoff BK1120 EtherCAT Bus Coupler links the EtherCAT fieldbus system with Beckhoff Bus Terminals, converting Ethernet 100BASE-TX telegrams to the internal terminal bus. It supports automatic process image assignment and enables modular expansion for flexible industrial I/O architectures.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Part Number BK1120
Manufacturer Beckhoff
Category PLCs/Machine Control
Subcategory PLC Module/Rack
Number of Bus Terminals 64 (255 with K-Bus extension)
Max. Fieldbus Data 1024 bytes input / 1024 bytes output
Configuration KS2000 or EtherCAT (ADS)
Data Transfer Rate 100 Mbit/s
Bus Interface 2 × RJ45
Medium Ethernet/EtherCAT Cat.5 cable
Power Supply 24 VDC (-15% / +20%)
Input Current 70 mA + K-Bus current/4 (max. 500 mA)
Starting Current Approx. 2.5× continuous current
Recommended Fuse ≤ 10 A
K-Bus Current Supply 1750 mA
Power Contacts Max. 24 VDC, 10 A
Electrical Isolation 500 V (contacts/supply/Ethernet)
Max. Station Distance 100 m (100BASE-TX)
Data Transfer Time 0.01 ms (10 modules, 32-bit I/O, no K-Bus runtime)
Operating Temp. –25…+60 °C
Storage Temp. –40…+85 °C
Relative Humidity 95% (non-condensing)
Vibration/Shock EN 60068-2-6 / EN 60068-2-27
EMC EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Weight Approx. 150 g
Approvals CE, UL, ATEX, IECEx

 

 

Information About BK1120

The Beckhoff BK1120 EtherCAT Bus Coupler provides seamless interfacing between the EtherCAT fieldbus and the Bus Terminal system by translating Ethernet 100BASE-TX telegrams into the internal, fieldbus-independent terminal bus. A standard station supports up to 64 Bus Terminals plus an end terminal, while the K-Bus extension allows installations to scale up to 255 terminals. The coupler integrates two RJ45 interfaces—one for upstream communication and the other for cascading downstream EtherCAT devices—enhancing network versatility. With direct 24 VDC system and field supply inputs, the BK1120 distributes communication and load power efficiently across connected terminals. Its robust isolation, high-speed transfer performance, and compliance with industrial standards make it a reliable backbone component for modular EtherCAT architectures.

Key Features:

  • High-speed EtherCAT interface: Converts Ethernet 100BASE-TX telegrams to the internal terminal bus for fast and deterministic communication.
  • Scalable system architecture: Supports 64 Bus Terminals natively and up to 255 terminals with K-Bus expansion, enabling large I/O stations.
  • Dual RJ45 ports: Allows network daisy-chaining and simplified EtherCAT topology design in complex installations.
  • Robust electrical design: 500 V isolation and 10 A power contacts ensure reliable operation in industrial environments.
  • Automatic process image assignment: Reduces configuration time and ensures seamless integration with EtherCAT masters.
  • Wide environmental tolerance: Operates from –25°C to +60°C with full industrial EMC compliance for harsh applications.
  • Flexible configuration options: Programmable via KS2000 or EtherCAT ADS for versatile system integration.

The BK1120 delivers the reliability and precision required for scalable, high-speed EtherCAT-based automation systems.