{"product_id":"42185-800-01-allen-bradley-3-pole-overload-relay-for-size-0-1-starters","title":"42185-800-01 | Allen-Bradley 3-Pole Overload Relay for Size 0–1 Starters","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley 42185-800-01 is a 3-pole overload relay designed for use with Size 0–1 motor starters to protect electric motors from overheating and overcurrent conditions. It operates across a wide AC voltage range and meets NEMA A600 control standards for dependable industrial performance. The Allen-Bradley 42185-800-01 is commonly applied in motor control circuits requiring reliable thermal overload protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactors \u0026amp; Starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42185-800-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid State Overload\/Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120–600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA A600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMake Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreak Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarter Size Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize 0–1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeater Elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequired (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen-style, starter-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.03 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 42185-800-01\u003c\/h4\u003e\n\u003cp\u003eThe 42185-800-01 is an Allen-Bradley overload relay engineered to provide essential motor protection in industrial control systems. It is designed for open-style mounting and integrates directly with compatible Size 0–1 starters. The relay detects excessive current draw that can lead to motor overheating and initiates protective action to prevent damage. Heater elements are required for proper operation, allowing the protection level to be matched precisely to the motor’s full-load current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-Pole Overload Protection: Monitors all three phases to protect motors from thermal overload.\u003c\/li\u003e\n\u003cli\u003eSize 0–1 Starter Compatibility: Designed for integration with standard Allen-Bradley Size 0–1 starters.\u003c\/li\u003e\n\u003cli\u003eWide Voltage Range: Supports AC control voltages from 120 to 600 VAC.\u003c\/li\u003e\n\u003cli\u003eNEMA A600 Rated: Meets NEMA standards for industrial motor control circuits.\u003c\/li\u003e\n\u003cli\u003eHigh Make Capacity: Rated for 7200 VA make capacity for robust switching performance.\u003c\/li\u003e\n\u003cli\u003eReliable Break Capacity: Provides 720 VA break capacity for safe circuit interruption.\u003c\/li\u003e\n\u003cli\u003eHeater Element Based Design: Uses replaceable heater elements to match motor current requirements.\u003c\/li\u003e\n\u003cli\u003eTest Module Support: Compatible with a test module for verification and maintenance checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 42185-800-01 delivers the reliability and precision required for motor overload protection in industrial starter and control applications.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49993044721962,"sku":"42185-800-01","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_abbe29b6-36c8-43e6-a8fe-a4475b634430.webp?v=1772015014","url":"https:\/\/iqelectro.com\/products\/42185-800-01-allen-bradley-3-pole-overload-relay-for-size-0-1-starters","provider":"IQElectro","version":"1.0","type":"link"}