{"product_id":"94dfr-n5-edwards-signaling-heavy-duty-strobe-light-120-vac-red-xenon-nema-4x","title":"94DFR-N5 | Edwards Signaling Heavy Duty Strobe Light 120 VAC Red Xenon NEMA 4X","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Edwards Signaling 94DFR-N5 Heavy Duty Strobe Light is a rugged, double xenon strobe beacon designed for high-visibility signaling in industrial and commercial environments. Operating on 120 VAC, it delivers powerful red flashes at 50 fpm for reliable visual alerts in both indoor and outdoor applications. Built with a cast steel housing and polycarbonate lens, it provides long-lasting performance under demanding conditions.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 431.064px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eEdwards Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eIndustrial Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e94DFR-N5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eStrobe Lights\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e94 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eHeavy Duty Double Strobe Beacon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eSurface Mount \/ 3\/4 in. Conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eXenon Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlash Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e50 Flashes Per Minute (fpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eLight Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e1,100,000 Peak Candlepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eLens Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eCast Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eUL 1638, cUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eIndoor and Outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eWater, Dust, and Corrosion Resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003eApprox. 6.5 x 5.0 x 5.0 in (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.1842%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.5965%; height: 19.5938px;\"\u003e3.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 94DFR-N5\u003c\/h4\u003e\n\u003cp\u003eThe 94DFR-N5 is part of the Edwards 94 Series of heavy-duty strobe beacons engineered for industrial signaling and warning systems. Designed to meet UL 1638 and cUL safety standards, it offers dependable performance in hazardous and harsh environments. The beacon features a NEMA 4X enclosure for protection against water, corrosion, and dust, ensuring durability in both indoor and outdoor installations. Its xenon flash tube provides intense illumination ideal for process control, emergency indication, and safety alerting systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Intensity Xenon Flash: Produces 1,100,000 peak candlepower for clear, visible alerts in bright or distant areas.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Heavy-duty cast steel housing and polycarbonate lens withstand industrial conditions.\u003c\/li\u003e\n\u003cli\u003eWide Voltage Compatibility: Operates at 120 VAC with low 0.1A current draw for energy-efficient performance.\u003c\/li\u003e\n\u003cli\u003eReliable Flash Rate: Delivers consistent 50 flashes per minute for attention-grabbing visual signaling.\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Rated Enclosure: Provides superior protection against water, dust, and corrosion for outdoor use.\u003c\/li\u003e\n\u003cli\u003eEasy Surface Mounting: Compatible with 3\/4-inch conduit connections for quick installation.\u003c\/li\u003e\n\u003cli\u003eUL and cUL Certified: Meets UL 1638 standards for visual signaling appliances.\u003c\/li\u003e\n\u003cli\u003eBright Red Lens: Enhances visibility for emergency, alarm, and warning applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 94DFR-N5 delivers the reliability and precision required for demanding industrial and safety signaling applications.\u003c\/p\u003e","brand":"Edwards Signaling","offers":[{"title":"Default Title","offer_id":50716988604714,"sku":"94DFR-N5","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l300_fc1642d8-5370-4ce6-b17d-a98bc7ed3f2f.webp?v=1760950510","url":"https:\/\/iqelectro.com\/products\/94dfr-n5-edwards-signaling-heavy-duty-strobe-light-120-vac-red-xenon-nema-4x","provider":"IQElectro","version":"1.0","type":"link"}