{"product_id":"abb-a210-30-11-210a-three-pole-industrial-power-contactor-690v","title":"ABB A210-30-11 210A Three-Pole Industrial Power Contactor 690V","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ABB A210-30-11 is a three-pole industrial power contactor designed for switching three-phase electrical loads and controlling high-power motors. It supports AC-3 operating currents up to 210 A and main-circuit voltages up to 690 V AC, making it suitable for demanding motor-starting and power distribution applications. The contactor includes an auxiliary contact arrangement for integration into industrial control circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 68.5815%; height: 423.556px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 53.25px;\"\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eNew\/Never Used Surplus\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5972px;\"\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eABB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 48.6806px;\"\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eAutomation Control Components\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 37.6944px;\"\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eA210-30-11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eContactors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eThree-Phase Power Contactor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eA Series\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e1SFL511001R8411\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMain Contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e3 NO\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e1 NO + 1 NC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operational Current (AC-3)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e210 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConventional Free-Air Thermal Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e350 A at 40°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003eUp to 690 V AC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e110 V AC at 50 Hz; 110–120 V AC at 60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e5 million cycles\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e140 × 180.5 × 227 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2858%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1837%;\"\u003e\n\u003cp\u003e11.9 lb \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eA210-30-11\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe A210-30-11 belongs to ABB's A-series of three-pole contactors, developed for industrial motor control and power switching applications. Its main contacts are designed for high-current operation, while the auxiliary contacts support control circuit functions and electrical interlocking. The specific ordering code 1SFL511001R8411 identifies the A210-30-11-84 version, with a 110 V AC coil at 50 Hz and 110–120 V AC at 60 Hz. The contactor supports installation in motor control centers, industrial machinery, pump systems, compressors, and other electrical distribution assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThree-Pole Configuration: Provides three main normally open contacts for switching three-phase electrical loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eHigh AC-3 Current Rating: Supports operational currents up to 210 A for motor control applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThermal Current Rating: Rated for conventional free-air thermal current up to 350 A at 40°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eMain Circuit Voltage: Supports rated operational voltages up to 690 V AC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAuxiliary Contacts: Includes one normally open and one normally closed auxiliary contact.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eCoil Voltage: 110 V AC at 50 Hz and 110–120 V AC at 60 Hz for the -84 version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eIndustrial Motor Control: Suitable for motor starting, isolation, bypass, and power distribution applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eMechanical Durability: Designed for up to 5 million mechanical operating cycles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe A210-30-11 delivers high-current switching performance and reliable control integration for industrial motor and power distribution systems.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53485766115626,"sku":"A210-30-11","price":967.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l960_d283590e-6266-4bd3-bb13-c4e6eeac581a.webp?v=1793999781","url":"https:\/\/iqelectro.com\/products\/abb-a210-30-11-210a-three-pole-industrial-power-contactor-690v","provider":"IQElectro","version":"1.0","type":"link"}