{"product_id":"abb-ach550-pdr-06a9-4-3-hp-hvac-variable-frequency-drive-with-disconnect","title":"ABB ACH550-PDR-06A9-4 3 HP HVAC Variable Frequency Drive with Disconnect","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ABB ACH550-PDR-06A9-4 is a packaged variable frequency drive designed for controlling three-phase AC motors in heating, ventilation, and air conditioning (HVAC) applications. It delivers a 3 HP (2.2 kW) motor power rating with a nominal output current of 6.9 A and operates from a 380–480 VAC three-phase supply. Its integrated disconnect switch and adjustable motor speed control make it suitable for commercial ventilation, pumping, and building automation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eDrives \u0026amp; Motor Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eACH550-PDR-06A9-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eHVAC Variable Frequency Drives\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eACH550\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003ePackaged Variable Frequency Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eHVAC, Fans and Pumps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMotor Power Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e3 HP \/ 2.2 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e380–480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Phase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e3-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Frequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e6.9 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eR1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003ePDR Packaged Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDisconnect Switch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication Protocols\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eBACnet MS\/TP, Modbus RTU, Johnson Controls N2, Siemens FLN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eControl Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e2 Internal PID Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eTimer Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003eReal-Time Clock with Programmable Timers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30.117%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.5906%; height: 19.6px;\"\u003e\u003cspan\u003e10.0 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About ACH550-PDR-06A9-4\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ACH550-PDR-06A9-4 belongs to ABB's ACH550 series of HVAC-specific variable frequency drives developed for fan and pump applications. The PDR configuration combines the drive with an integrated disconnect switch and protective components within a packaged enclosure. Its control architecture includes dedicated HVAC functions, two internal PID controllers, and a real-time clock with programmable timer functions. Built-in communication interfaces support BACnet MS\/TP, Modbus RTU, Johnson Controls N2, and Siemens FLN protocols for integration with building management and industrial automation systems.\u003c\/p\u003e\n\u003ch4 dir=\"auto\" data-start=\"456\" data-end=\"1011\" class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eMotor Power Rating: Supports three-phase motor applications up to 3 HP (2.2 kW).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eOutput Current: Provides a rated output current of 6.9 A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eInput Voltage: Operates with a 380–480 VAC three-phase power supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eIntegrated Disconnect: Includes a disconnect switch for electrical isolation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eHVAC Control: Designed for commercial fans, pumps, ventilation, and air conditioning systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eCommunication Protocols: Supports BACnet MS\/TP, Modbus RTU, Johnson Controls N2, and Siemens FLN.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003ePID Controllers: Includes two internal PID control loops for process regulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFrame Configuration: Uses the compact R1 frame configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ACH550-PDR-06A9-4 delivers the reliability and precision required for HVAC motor regulation, commercial ventilation, and automated pumping applications.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53469706354986,"sku":"ACH550-PDR-06A9-4","price":2102.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_9c823b1f-71c8-4544-a3eb-0790ebae4094.webp?v=1793904690","url":"https:\/\/iqelectro.com\/products\/abb-ach550-pdr-06a9-4-3-hp-hvac-variable-frequency-drive-with-disconnect","provider":"IQElectro","version":"1.0","type":"link"}