{"product_id":"abb-ot200u03-three-pole-non-fusible-switch-disconnector","title":"ABB OT200U03 Three-Pole Non-Fusible Switch-Disconnector","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003eThe ABB OT200U03 is a three-pole, non-fusible switch-disconnector rated at 200 A and up to 600 VAC under UL\/CSA requirements. It provides manual load switching and electrical isolation for machinery, motor circuits, and power-distribution equipment. Its base-mounted construction supports installation within a suitable electrical enclosure.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 81.5728%; height: 470.251px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003ePower Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eOT200U03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eNon-Fusible Switch-Disconnectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eUL\/CSA Ampere Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Operating Voltage, UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 39.1875px;\"\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 39.1875px;\"\u003e\u003cstrong\u003eIEC Operational Current, AC-22A \/ AC-23A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 39.1875px;\"\u003e250 A at 380–415, 500, and 690 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 39.1875px;\"\u003e\u003cstrong\u003eIEC Motor Power, AC-23A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 39.1875px;\"\u003e110 kW at 380–415 V; 132 kW at 500 V; 200 kW at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 39.1875px;\"\u003e\u003cstrong\u003eThree-Phase Motor Ratings, UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 39.1875px;\"\u003e60 HP at 200\/208 V; 75 HP at 240 V; 150 HP at 480 V; 200 HP at 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eBase mounting \/ panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eFront operated; mechanism at left end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupply Connection Direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eTop-in\/bottom-out or bottom-in\/top-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 39.1875px;\"\u003eHandle and shaft ordered separately; terminal bolt kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003eIEC 60947-3; UL 98; CSA C22.2 No. 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003e169.5 × 170 × 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd align=\"left\" style=\"width: 39.7319%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\" style=\"width: 60.0515%; height: 19.5938px;\"\u003e1.5 kg (3.31 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan\u003eInformation \u003c\/span\u003e\u003cspan\u003eAbout \u003cspan data-sheets-root=\"1\"\u003eOT200U03\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003eThe OT200U03 is part of ABB’s OT switch-disconnector range and uses a front-operated mechanism positioned at the left end of the switch. The design permits supply connections from either the top or bottom terminals. ABB supplies the switch with a terminal bolt kit, while the operating handle and shaft are ordered separately. This configuration supports assembly into compatible panelboards, switchboards, and industrial control panels.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThree-Pole Switching: Connects or isolates three power conductors through a common operating mechanism.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUL\/CSA Current Rating: Provides a 200 A rating for applications up to 600 VAC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNon-Fusible Construction: Provides switching and isolation, with circuit protection supplied by separate devices.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFront Operation: Uses an operating mechanism located at the left end of the switch.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBase Mounting: Supports installation on a panel or mounting plate within suitable equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReversible Supply Direction: Permits top-in\/bottom-out or bottom-in\/top-out connections.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMotor Switching Ratings: Rated for 75 HP at 240 VAC, 150 HP at 480 VAC, and 200 HP at 600 VAC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeparate Operating Accessories: Allows selection of a compatible handle and shaft for the installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe OT200U03 delivers the reliability and precision required for manual load switching and circuit isolation in industrial electrical installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"2127\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"703\" data-end=\"1384\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"730\" data-end=\"1339\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1027\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1720\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"964\" data-end=\"1745\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"895\" data-end=\"1639\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"999\" data-end=\"1761\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"937\" data-end=\"1684\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"865\" data-end=\"1570\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"959\" data-end=\"1674\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"968\" data-end=\"1715\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1019\" data-end=\"1782\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"873\" data-end=\"1681\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1089\" data-end=\"1853\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1030\" data-end=\"1752\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"889\" data-end=\"1649\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"968\" data-end=\"1691\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"885\" data-end=\"1615\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"878\" data-end=\"1601\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003col start=\"3\"\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003col start=\"3\"\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52955828486442,"sku":"OT200U03","price":647.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1200_d1afc68f-ea18-4c97-a0b3-b7ae599a16cb.jpg?v=1792090678","url":"https:\/\/iqelectro.com\/products\/abb-ot200u03-three-pole-non-fusible-switch-disconnector","provider":"IQElectro","version":"1.0","type":"link"}