{"product_id":"abb-pr122-p-lsig-sace-emax-electronic-trip-unit","title":"ABB PR122\/P-LSIG SACE Emax Electronic Trip Unit","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ABB PR122\/P-LSIG is an electronic protection trip unit designed for compatible ABB SACE Emax low-voltage air circuit breakers. It provides advanced protection against overloads, short circuits, and earth faults, helping safeguard electrical distribution systems and connected equipment. Its microprocessor-based design also supports measurement, event monitoring, self-diagnostics, and selective coordination of circuit breakers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePR122\/P-LSIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic Circuit Breaker Trip Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Family\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSACE Emax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic Protection Trip Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLSIG: Long-time, Short-time, Instantaneous, Ground Fault\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Breaker Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB SACE Emax low-voltage air circuit breakers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBreaker Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible 3-pole and 4-pole models\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroprocessor-based electronic protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLong-Time Current Setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4–1.0 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eShort-Time Current Setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6–10 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInstantaneous Current Setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5–15 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGround-Fault Current Setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2–1.0 × In\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCommunication \/ Expansion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional modules, depending on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cmeta charset=\"utf-8\"\u003e PR122\/P-LSIG\u003c\/h4\u003e\n\u003cp\u003eThe PR122\/P-LSIG belongs to ABB's SACE Emax electronic trip-unit family and is designed for compatible three-pole and four-pole air circuit breakers. Its LSIG protection functions include long-time overload, short-time short-circuit, instantaneous short-circuit, and ground-fault protection. Adjustable trip thresholds and time delays allow protection settings to be coordinated with the electrical installation. Depending on the configuration, additional modules can provide communication, voltage measurement, and expanded monitoring functions.\u003c\/p\u003e\n\u003ch4 dir=\"auto\" data-start=\"456\" data-end=\"1011\" class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features:\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectronic Trip Technology:\u003c\/span\u003e \u003cspan\u003eMicroprocessor-based \u003c\/span\u003e\u003cspan\u003eprotection \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eABB \u003c\/span\u003e\u003cspan\u003eEmax \u003c\/span\u003e\u003cspan\u003ecircuit \u003c\/span\u003e\u003cspan\u003ebreakers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLSIG Protection:\u003c\/span\u003e \u003cspan\u003eCombines \u003c\/span\u003e\u003cspan\u003elong-time, \u003c\/span\u003e\u003cspan\u003eshort-time, \u003c\/span\u003e\u003cspan\u003einstantaneous, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eground-fault \u003c\/span\u003e\u003cspan\u003eprotection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable Overload Protection:\u003c\/span\u003e \u003cspan\u003eConfigurable \u003c\/span\u003e\u003cspan\u003elong-time \u003c\/span\u003e\u003cspan\u003ecurrent \u003c\/span\u003e\u003cspan\u003ethresholds \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003edelay \u003c\/span\u003e\u003cspan\u003esettings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eShort-Circuit Protection:\u003c\/span\u003e \u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003eadjustable \u003c\/span\u003e\u003cspan\u003eshort-time \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003einstantaneous \u003c\/span\u003e\u003cspan\u003etrip \u003c\/span\u003e\u003cspan\u003efunctions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eGround-Fault Protection:\u003c\/span\u003e \u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eadjustable \u003c\/span\u003e\u003cspan\u003eearth-fault \u003c\/span\u003e\u003cspan\u003eprotection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSelective Coordination:\u003c\/span\u003e \u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003ecoordination \u003c\/span\u003e\u003cspan\u003ebetween \u003c\/span\u003e\u003cspan\u003eupstream \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003edownstream \u003c\/span\u003e\u003cspan\u003ebreakers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement and Monitoring:\u003c\/span\u003e \u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003einformation \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003etrip \u003c\/span\u003e\u003cspan\u003eunit's \u003c\/span\u003e\u003cspan\u003euser \u003c\/span\u003e\u003cspan\u003einterface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOptional Expansion Modules:\u003c\/span\u003e \u003cspan\u003eCompatible \u003c\/span\u003e\u003cspan\u003econfigurations \u003c\/span\u003e\u003cspan\u003ecan \u003c\/span\u003e\u003cspan\u003esupport \u003c\/span\u003e\u003cspan\u003eadditional \u003c\/span\u003e\u003cspan\u003emeasurement \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ecommunication \u003c\/span\u003e\u003cspan\u003efunctions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003ePR122\/P-LSIG \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003econfigurable \u003c\/span\u003e\u003cspan\u003eelectronic \u003c\/span\u003e\u003cspan\u003eprotection \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003emonitoring \u003c\/span\u003e\u003cspan\u003ecapabilities \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eABB \u003c\/span\u003e\u003cspan\u003eSACE \u003c\/span\u003e\u003cspan\u003eEmax \u003c\/span\u003e\u003cspan\u003epower \u003c\/span\u003e\u003cspan\u003edistribution \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53021040017706,"sku":"PR122\/P-LSIG","price":4997.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_80108251-5306-4a09-9a52-3812877f344e.webp?v=1792400755","url":"https:\/\/iqelectro.com\/products\/abb-pr122-p-lsig-sace-emax-electronic-trip-unit","provider":"IQElectro","version":"1.0","type":"link"}