{"product_id":"aes-7707p-88-ulp-m-fire-communicator-fast-shipping","title":"AES 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber Wireless Fire Alarm Communicator","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"493\" data-start=\"17\"\u003eThe AES 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber is a supervised fire alarm communication device designed for reliable RF signal transmission across AES wireless mesh networks. It provides eight programmable alarm input zones, integrated annunciation, and advanced fire alarm reporting capabilities for commercial and industrial life-safety applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 81.7029%; height: 646.595px;\" height=\"717\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eAES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eFire Alarm Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e7707P-88-ULP-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eWireless Fire Alarm Communicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eIntelliNet 2.0 Fire Subscriber Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 39.1875px;\"\u003e\u003cstrong\u003eCommunication Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 39.1875px;\"\u003eRF Signaling Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupported Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e8 Supervised Programmable Fire Alarm Zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e450–470 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eAntenna Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e2.5 dB Tamper Resistant Antenna Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 39.1875px;\"\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 39.1875px;\"\u003e16.5 VAC Class 2 Transformer or 24 VDC Regulated Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eRF Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e2 W or 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eUSB Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e2 x 20 Character Backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eVisual Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eLCD Display, ALM, Trouble, Tx, Rx, WA LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrouble Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eForm C Relay, 24 VDC, 1 A Resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 39.1875px;\"\u003e\u003cstrong\u003eProgramming Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 39.1875px;\"\u003eWeb Browser Accessible via Smartphone, Tablet, Laptop, or PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 39.1875px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e14°F to 140°F (-10°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e0–93% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003ePainted Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 39.1875px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 39.1875px;\"\u003e13 in H × 8.5 in W × 4.5 in D (33 × 21.5 × 11.4 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003eUL 864 Edition 10, ULC S559-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.7212%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.0113%; height: 19.5938px;\"\u003e16 lbs (7.2 kg) with 12 Ah Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e7707P-88-ULP-M\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1240\" data-start=\"518\"\u003eThe 7707P-88-ULP-M is a member of the AES IntelliNet 2.0 series of wireless fire alarm communicators engineered for code-compliant fire signal transmission. Constructed within a durable steel enclosure with an integrated LCD display and local annunciator, it is designed for installation in fire alarm and life-safety systems requiring supervised radio communication. The unit supports multiple signaling formats through the IntelliPro Full Data module and can interface with compatible fire alarm control panels using programmable supervised inputs. Advanced networking capabilities, Ethernet connectivity, web-based configuration, and AES mesh radio technology provide flexible deployment and system management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2143\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eIntelliNet 2.0 Technology: Utilizes AES wireless mesh network architecture for supervised alarm communication.\u003c\/li\u003e\n\u003cli\u003eEight Programmable Zones: Supports 8 individually programmable E.O.L. supervised alarm input zones.\u003c\/li\u003e\n\u003cli\u003eIntegrated LCD Annunciator: Features a backlit 2 x 20 alphanumeric display for local status monitoring.\u003c\/li\u003e\n\u003cli\u003eFull Data Communication: Supports Contact ID, Pulse, Modem II\/IIe\/IIIa2, and SIA Level 1 reporting with optional 7794A module.\u003c\/li\u003e\n\u003cli\u003eFlexible Power Options: Operates from 16.5 VAC transformer input or regulated 24 VDC power sources.\u003c\/li\u003e\n\u003cli\u003eEthernet and USB Connectivity: Includes one Ethernet port and two USB ports for configuration and servicing.\u003c\/li\u003e\n\u003cli\u003eRF Communication Capability: Available in the 450–470 MHz frequency range with configurable output power options.\u003c\/li\u003e\n\u003cli\u003eUL Fire System Compliance: Listed to UL 864 and ULC S559 standards for fire alarm communication applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 7707P-88-ULP-M\u003cspan\u003e delivers the reliability and precision required for supervised fire alarm communication and life-safety monitoring systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"AES","offers":[{"title":"Default Title","offer_id":51657239101738,"sku":"7707P-88-ULP-M","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/7707P-88-M-Featured.png?v=1780935108","url":"https:\/\/iqelectro.com\/products\/aes-7707p-88-ulp-m-fire-communicator-fast-shipping","provider":"IQElectro","version":"1.0","type":"link"}