{"product_id":"alerton-bcm-eth-bactalk-bacnet-ethernet-and-ms-tp-global-controller","title":"Alerton BCM-ETH BACtalk BACnet Ethernet and MS\/TP Global Controller","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eAlerton BCM-ETH is a BACnet router and global controller designed to connect BACnet Ethernet and BACnet MS\/TP networks within building automation systems. It provides network routing, global control, and BACnet\/IP communication for HVAC and facility automation applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 375.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eAlerton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBuilding Automation \/ HVAC Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBCM-ETH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBACnet Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBACnet Router and Global Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eBACnet Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBACnet Building Controller (B-BC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBACnet Ethernet \/ BACnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eField Network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eBACnet MS\/TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eMS\/TP Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eUp to 65 field controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eMS\/TP Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003e9.6 to 76.8 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eBBMD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eAlarm Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eUp to 320 alarm setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrend Logs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003eUp to 320 trend logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003e0–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003e166 × 39 × 127 mm (6.5 × 1.5 × 5.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 22.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 22.5938px;\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6611%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8643%; height: 19.5938px;\"\u003e0.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eBCM-ETH\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe BCM-ETH is part of the Alerton BACtalk Control Module platform and is designed for integration with Alerton building automation networks. Its Ethernet interface provides BACnet\/IP connectivity, while the MS\/TP connection links field controllers using an RS-485 network. The controller can operate as a BACnet Broadcast Management Device (BBMD) to manage BACnet\/IP broadcast traffic across routed networks. It is also a BACnet Building Controller (B-BC) and supports centralized control and monitoring functions within a BAS environment.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet Router: Routes BACnet traffic between Ethernet\/IP and MS\/TP networks.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eGlobal Controller: Provides centralized building automation control functions.\u003c\/li\u003e\n\u003cli\u003eBACnet\/IP: Supports BACnet communication over Ethernet networks.\u003c\/li\u003e\n\u003cli\u003eMS\/TP Interface: Connects compatible BACnet field controllers through an MS\/TP bus.\u003c\/li\u003e\n\u003cli\u003eBBMD Support: Functions as a BACnet Broadcast Management Device for routed IP networks.\u003c\/li\u003e\n\u003cli\u003eB-BC Profile: Listed as a BACnet Building Controller under BACnet Testing Laboratories.\u003c\/li\u003e\n\u003cli\u003eHVAC Integration: Designed for HVAC, energy management, and building automation applications.\u003c\/li\u003e\n\u003cli\u003eScalable Architecture: Supports integration with distributed Alerton control modules and field controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe BCM-ETH delivers the reliability and precision required for BACnet network routing, global control, and building automation system integration. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Alerton","offers":[{"title":"Default Title","offer_id":52717223182634,"sku":"BCM-ETH","price":1237.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_c20edcc8-0228-4605-abca-b2a88a8af07c.jpg?v=1790002120","url":"https:\/\/iqelectro.com\/products\/alerton-bcm-eth-bactalk-bacnet-ethernet-and-ms-tp-global-controller","provider":"IQElectro","version":"1.0","type":"link"}