{"product_id":"allen-bradley-2094-bc01-mp5-s-axis-module-quick-delivery","title":"2094-BC01-MP5-S | Allen-Bradley Kinetix 6000 Integrated Axis Module 400\/460V 6 kW STO","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"451\" data-start=\"0\"\u003eThe Allen-Bradley 2094-BC01-MP5-S is a 400 Volt class Integrated Axis Module (IAM) for the Kinetix 6000 motion control system. It operates from a 360–480 VAC three-phase supply and delivers 6 kW continuous output power with 9 A continuous bus current. The module includes integrated Safe Torque Off (STO) functionality and supports both AC input and common bus DC follower operation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eServo Drives \/ Motion Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e2094-BC01-MP5-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eIntegrated Axis Module (IAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eIAM, 400 Volt Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003ePower Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eAC Input Voltage (Range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e324–528 VAC, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eAC Input Voltage (Nominal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e360\/480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eAC Input Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eAC Input Current (Nominal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eAC Input Current (Max Inrush)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eDC Input Voltage (Follower Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e458–747 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eDC Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eContinuous Power Output to Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003ePeak Power Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eBus Undervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e275 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eBus Overvoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e425 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eInternal Shunt (Continuous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eInternal Shunt (Peak)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e5.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eInternal Shunt Resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e115 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eMinimum Enclosure Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e198 mm (7.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eInstallation Clearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eIntegrated Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eSafe Torque Off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eSupported Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eSERCOS (via 1756-M0xSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.4169%;\"\u003e\u003cstrong\u003eCompatible Motors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3638%;\"\u003eKinetix MP, TL\/TLY, RDB, 1326AB, LDAT\/LDC\/LDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 2094-BC01-MP5-S\u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"1074\" data-start=\"590\"\u003eThe 2094-BC01-MP5-S is part of the Allen-Bradley Kinetix 6000 servo drive platform and functions as an IAM mounted directly on the system power rail. It provides both power conversion and axis control, enabling multi-axis servo systems through a modular architecture. The module supports AC input voltages from 324–528 V RMS and DC bus follower inputs from 458–747 VDC, allowing flexible installation and energy-sharing configurations. It integrates with ControlLogix PAC systems through SERCOS interface modules and supports a wide range of Kinetix and legacy servo motors. Typical applications include coordinated motion, robotics, material handling systems, and high-performance automation equipment requiring deterministic motion control and integrated safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e6 kW continuous bus output: Delivers 9 A continuous output for servo applications.\u003c\/li\u003e\n\u003cli\u003e400 V class IAM: Operates from 360–480 VAC, 3-phase supply.\u003c\/li\u003e\n\u003cli\u003eIntegrated Safe Torque Off (STO): Enhances system safety by disabling torque without removing power.\u003c\/li\u003e\n\u003cli\u003eSupports common bus follower mode: Accepts 458–747 VDC bus input and 9 A DC current.\u003c\/li\u003e\n\u003cli\u003eModular Kinetix 6000 design: Mounts to the system power rail with other axis and shunt modules.\u003c\/li\u003e\n\u003cli\u003eSERCOS interface compatibility: Enables fast, deterministic communication with ControlLogix controllers.\u003c\/li\u003e\n\u003cli\u003eHigh efficiency: Rated at 97% for minimal thermal losses.\u003c\/li\u003e\n\u003cli\u003eWide motor compatibility: Works with Kinetix MP\/TL\/TLY, RDB, 1326AB, and linear actuators (LDAT, LDC, LDL).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 2094-BC01-MP5-S delivers the reliability and precision required for advanced multi-axis servo motion systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47579713306922,"sku":"2094-BC01-MP5-S","price":4135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/2094-BC01-MP5-S.webp?v=1708690863","url":"https:\/\/iqelectro.com\/products\/allen-bradley-2094-bc01-mp5-s-axis-module-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}