{"product_id":"asco-8220g013-2-inch-normally-closed-hot-water-and-steam-solenoid-valve-120v-ac","title":"Asco 8220G013 2-Inch Normally Closed Hot Water and Steam Solenoid Valve 120V AC","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eAsco 8220G013 is a RedHat Series 8220 pilot-operated solenoid valve designed for controlling hot water and steam in industrial systems. It features a 2-inch NPTF connection, normally closed 2-way configuration, brass body, and a high-flow Cv rating of 43. The valve operates at 120V AC\/60 Hz or 110V AC\/50 Hz and supports hot-water pressures up to 150 psi.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 89.9785%; height: 402.413px;\" height=\"610\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 26.8125px;\"\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.8125px;\"\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eAsco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.8125px;\"\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eIndustrial Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.8125px;\"\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e8220G013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.8125px;\"\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eSolenoid Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.0375px;\"\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eRedHat 8220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eHot Water and Steam Solenoid Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eValve Ways\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e2-Way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eValve Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e2-Position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eValve Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eOperation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003ePilot Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eValve Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eDiaphragm and Piston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eNPTF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eOrifice Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e1-3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eFlow Coefficient (Cv)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eEPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e120V AC \/ 60 Hz; 110V AC \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eWattage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e10.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eMinimum Operating Pressure Differential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e5 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eHot Water Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e5–150 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eSteam Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e5–50 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eMaximum Hot Water Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e210°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eMaximum Steam Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e300°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e14°F to 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e1\/2 in Conduit with 18 in Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eCoil Insulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eClass F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eCoil Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eWatertight, Without Junction Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e1, 2, 3, 3S, 4, 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eOverall Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e7-1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e5-1\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eOverall Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e4-23\/32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003eCSA, UL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.4135%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 45.3446%;\"\u003e10 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e8220G013\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 8220G013 is an Asco Series 8220 solenoid valve using a pilot-operated diaphragm and piston design for high-temperature fluid control. Its 2-inch flow path incorporates a 1-3\/4-inch orifice and EPDM sealing material, providing a Cv coefficient of 43. The valve requires a minimum operating pressure differential of 5 psi and is rated for steam service up to 50 psi and hot-water service up to 150 psi. Its watertight RedHat enclosure supports NEMA 1, 2, 3, 3S, 4, and 4X environmental ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eNormally Closed Configuration: Maintains the flow path closed while the solenoid is de-energized.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePilot-Operated Design: Uses a diaphragm and piston mechanism for controlled operation in high-flow hot-water and steam systems.\u003c\/li\u003e\n\u003cli\u003e2-Inch NPTF Ports: Provides large threaded inlet and outlet connections for industrial piping installations.\u003c\/li\u003e\n\u003cli\u003eHigh Flow Capacity: Features a 1-3\/4-inch orifice with a Cv coefficient of 43. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot-Water Service: Supports operating pressure differentials from 5 to 150 psi and fluid temperatures up to 210°F. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSteam Service: Rated for 5 to 50 psi steam pressure differential and temperatures up to 300°F. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDual-Frequency Coil: Operates at 120V AC\/60 Hz or 110V AC\/50 Hz with 10.1 W power consumption. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eWatertight Enclosure: NEMA 1, 2, 3, 3S, 4, and 4X ratings support indoor, outdoor, and washdown installations. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 8220G013 delivers the reliability and precision required for high-flow hot-water and steam control in industrial systems.\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":52562476990762,"sku":"8220G013","price":2255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_2c27137c-873e-483d-b1f9-8d0e310c48f6.webp?v=1789062688","url":"https:\/\/iqelectro.com\/products\/asco-8220g013-2-inch-normally-closed-hot-water-and-steam-solenoid-valve-120v-ac","provider":"IQElectro","version":"1.0","type":"link"}