{"product_id":"balluff-bni005h-profinet-io-link-master-module","title":"Balluff BNI005H PROFINET IO-Link Master Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe Balluff BNI005H is a PROFINET network module designed to connect industrial sensors and actuators to higher-level automation systems through IO-Link. It provides eight IO-Link ports, configurable digital inputs and outputs, and an IP67-rated metal housing for reliable operation in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e \u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 406px; max-width: 100%; font-size: 14px; height: 497px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003eBalluff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003eIndustrial Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003eBNI005H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 177.948px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 202.052px;\"\u003ePROFINET IO-Link Master Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eAuxiliary Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e8 × IO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eIO-Link Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003ePort Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e18–30.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e16 × PNP, Type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e16 × PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eSensor Current Sum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e9.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eActuator Current Sum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e9.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 177.948px;\"\u003e\u003cstrong\u003eCommunication Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 202.052px;\"\u003e2 × M12 × 1, 4-pin, D-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eSupply Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e7\/8-inch, 5-pin input and output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e−5 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 177.948px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 202.052px;\"\u003e0.67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About BNI005H\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe Balluff BNI005H, model BNI PNT-508-105-Z015, is part of Balluff's Silver Line network modules for specialized applications. It supports PROFINET communication and provides eight Type A IO-Link ports for connecting compatible sensors and actuators. The module operates from an 18–30.2 VDC supply and supports configurable PNP digital inputs and outputs. Its die-cast zinc housing, integrated display, and IP67 protection rating make it suitable for machine-level installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePROFINET Interface: Enables communication between connected field devices and compatible industrial controllers.\u003c\/li\u003e\n\u003cli\u003eEight IO-Link Ports: Connects up to eight compatible IO-Link sensors and actuators.\u003c\/li\u003e\n\u003cli\u003eConfigurable Digital I\/O: Provides 16 PNP digital inputs and 16 PNP digital outputs.\u003c\/li\u003e\n\u003cli\u003e18–30.2 VDC Supply: Operates across a wide industrial DC voltage range.\u003c\/li\u003e\n\u003cli\u003eIP67 Protection: Provides dust-tight protection and resistance to temporary water immersion under specified conditions.\u003c\/li\u003e\n\u003cli\u003eIntegrated Display: Supports local status monitoring and diagnostics.\u003c\/li\u003e\n\u003cli\u003eFast Start-Up Support: Supports Fast Start-Up functionality for compatible PROFINET applications.\u003c\/li\u003e\n\u003cli\u003eRugged Metal Housing: Features nickel-plated die-cast zinc construction for industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Balluff BNI005H provides distributed I\/O and IO-Link connectivity for compatible PROFINET industrial automation systems.\u003c\/p\u003e","brand":"Balluff","offers":[{"title":"Default Title","offer_id":52951613473066,"sku":"BNI005H","price":805.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_f3fa4766-8c31-4bae-b672-8d255708d7ec.webp?v=1792066942","url":"https:\/\/iqelectro.com\/products\/balluff-bni005h-profinet-io-link-master-module","provider":"IQElectro","version":"1.0","type":"link"}