{"product_id":"banner-sc10-2roe-safety-controller-quick-delivery","title":"SC10-2ROE | Banner Safety Controller with 10 Inputs and Dual Relay Outputs","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"679\" data-start=\"333\"\u003eThe Banner SC10-2ROE safety controller is a compact base controller designed for machine safety monitoring and control applications. It provides configurable safe inputs and dual relay outputs to manage safety devices such as emergency stops, light curtains, and interlocks. This controller supports in-series diagnostics for improved fault detection and system reliability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 509.439px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eBanner Engineering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eSafety Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eSC10-2ROE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eSafety Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eBase Safety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e0.24 A (no load), 0.53 A (full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Safe Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 39.1875px;\"\u003e\u003cstrong\u003eNumber of Convertible Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 39.1875px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eConfigurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 39.1875px;\"\u003e\u003cstrong\u003eSafety Output Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 39.1875px;\"\u003e2 sets of 3 NO relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafe Output Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eNon-Safe Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eUp to 4 PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eNon-Safe Output Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e80 mA @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eIn-Series Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Category Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eCategory 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003ePL e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eSIL Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003eUp to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e90% @ 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003ePush-In Spring Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e115 x 45 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.1145%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.6662%; height: 19.5938px;\"\u003e1.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SC10-2ROE\u003c\/h4\u003e\n\u003cp data-end=\"1273\" data-start=\"711\"\u003eThe SC10-2ROE is part of Banner Engineering’s SC10 safety controller family, designed as a standalone base controller for safety-critical applications. It supports up to two ISD chains and includes ten configurable safety inputs, four of which can be converted for non-safety use. The controller is engineered for direct wiring of safety devices using push-in spring clamp terminals and operates on a 24 V dc supply. Its architecture supports high safety integrity levels, making it suitable for machinery requiring Category 4, PL e, and SIL 3 compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eISD Compatibility: Supports two in-series diagnostic chains for advanced fault detection.\u003c\/li\u003e\n\u003cli\u003eTen Configurable Safe Inputs: Allows flexible connection of multiple safety devices.\u003c\/li\u003e\n\u003cli\u003eDual Relay Safety Outputs: Provides two independently controlled relay outputs rated at 6 A.\u003c\/li\u003e\n\u003cli\u003eConvertible Inputs: Includes four inputs that can be configured for non-safety functions.\u003c\/li\u003e\n\u003cli\u003eHigh Safety Ratings: Certified to Category 4, PL e, and SIL 3 requirements.\u003c\/li\u003e\n\u003cli\u003eCompact DIN-Mount Design: Optimized for control panels with limited space.\u003c\/li\u003e\n\u003cli\u003ePush-In Spring Clamp Terminals: Enables secure and tool-free wiring connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SC10-2ROE delivers the reliability and precision required for machine safety control and industrial safeguarding systems.\u003c\/p\u003e","brand":"Banner","offers":[{"title":"Default Title","offer_id":51107089285418,"sku":"SC10-2ROE","price":609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_57e0a5d9-e5c1-4789-8836-6d1c7101ee3e.webp?v=1770021607","url":"https:\/\/iqelectro.com\/products\/banner-sc10-2roe-safety-controller-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}