{"product_id":"beckhoff-ek1110-0008-ethercat-extension-module-ships-fast","title":"EK1110-0008 | Beckhoff EtherCAT Extension with M8 Socket, 100 Mbit\/s","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"444\" data-start=\"90\"\u003eThe Beckhoff EK1110-0008 EtherCAT Extension is designed to extend EtherCAT networks in line topology configurations using an M8 connection interface. It converts E-bus signals into 100BASE-TX Ethernet signals, enabling connection of additional EtherCAT devices or segments up to 100 meters away without configuration.\u003c\/p\u003e\n\u003ch3 data-end=\"534\" data-start=\"502\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eBeckhoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eIndustrial Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eEK1110-0008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eEtherCAT Extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eExtension of EtherCAT network with M8 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eTask Within System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eConverts E-bus to 100BASE-TX Ethernet for network extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eData Transfer Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eEthernet\/EtherCAT cable (min. Cat.5), shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eEtherCAT (any protocol supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e1 x M8 socket, shielded, screw type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eMaximum Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e100 m (100BASE-TX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eDelay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eApprox. 1 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eFrom E-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eCurrent Consumption (E-bus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eTyp. 130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e500 V (supply voltage\/Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eEMC Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eEN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e-25…+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e-40…+85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0309%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.6544%;\"\u003e50 g (approx. 0.11 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eEK1110-0008\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe EK1110-0008 belongs to Beckhoff’s EtherCAT infrastructure series, enabling seamless expansion of EtherCAT segments through M8 connectivity. It connects directly to the end of an EtherCAT Terminal segment or Embedded PC (CX series), extending communication lines up to 100 meters using a standard Ethernet cable with an M8 connector. The device performs continuous conversion from E-bus signals to 100BASE-TX Ethernet format, maintaining signal integrity and synchronization across extended networks. With power supplied via the E-bus and no configuration required, the EK1110-0008 simplifies network design and supports consistent cabling for both IP20 and IP67 system environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEtherCAT Line Extension: Allows easy expansion of EtherCAT networks using line topology, linking additional terminals or remote devices.\u003c\/li\u003e\n\u003cli\u003eM8 Socket Interface: Equipped with a shielded M8 connector for reliable Ethernet cabling in industrial environments.\u003c\/li\u003e\n\u003cli\u003eSignal Conversion: Continuously converts E-bus signals to 100BASE-TX Ethernet representation for smooth data transmission.\u003c\/li\u003e\n\u003cli\u003eLong-Distance Communication: Supports connection lengths up to 100 meters, maintaining high network integrity and low latency.\u003c\/li\u003e\n\u003cli\u003eMaintenance-Free Operation: Requires no configuration or parameterization, reducing setup time and simplifying commissioning.\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Data Rate: Operates at 100 Mbit\/s for fast, deterministic EtherCAT communication.\u003c\/li\u003e\n\u003cli\u003eElectrical Isolation: 500 V isolation between supply voltage and Ethernet ensures system protection and reliability.\u003c\/li\u003e\n\u003cli\u003eRobust and Compact Design: IP20-rated, lightweight housing suitable for DIN-rail installation in control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EK1110-0008 delivers the reliability and precision required for efficient EtherCAT network expansion and industrial communication continuity.\u003c\/p\u003e","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":50754086961450,"sku":"EK1110-0008","price":587.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/ek1110-0008__web_preview.png?v=1761754442","url":"https:\/\/iqelectro.com\/products\/beckhoff-ek1110-0008-ethercat-extension-module-ships-fast","provider":"IQElectro","version":"1.0","type":"link"}