{"product_id":"beckhoff-el1918-safety-input-terminal-2-year-warranty","title":"EL1918 | Beckhoff 8-Channel TwinSAFE EtherCAT Safety Input Terminal","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Beckhoff EL1918 is an EtherCAT safety input terminal featuring eight fail-safe digital inputs for integration into TwinSAFE systems. It transmits input signals using the Safety over EtherCAT (FSoE) protocol to a TwinSAFE Logic-capable device. The EL1918 enables configurable test pulses and flexible parameterization to support a wide range of safety sensors and application requirements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBeckhoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherCAT I\/O Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEL1918\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Input Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwinSAFE \/ Safety over EtherCAT (FSoE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 fail-safe inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-\/2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ watchdog time (parameterizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (E-Bus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etyp. 165 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD housing with signal LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 × 100 × 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIN Rail Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSide-by-Side Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble slot and key connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBZxxx series labeling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in (solid); spring-actuated (stranded\/ferrules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003es: 0.08–1.5 mm²; st: 0.25–1.5 mm²; f: 0.14–0.75 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003es: AWG 28–16; st: AWG 22–16; f: AWG 26–19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8–9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Contacts Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImax: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail with locking mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-density safety input terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About EL1918\u003c\/h4\u003e\n\u003cp\u003eThe EL1918 is part of Beckhoff’s TwinSAFE safety series and is designed as an eight-channel safety input terminal with configurable operating parameters. It is built in a compact HD-style housing with LED indicators and supports 1- or 2-wire connection technology for diverse safety sensor types. The module integrates seamlessly into TwinSAFE architectures and can transmit safety-relevant signals via FSoE to controllers such as EL6910-based systems. Typical applications include emergency stop circuits, light curtains, safety switches, and other SIL-oriented safety devices requiring configurable test pulses and safe digital input processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEight Fail-Safe Inputs: Supports safe digital signal acquisition for various certified safety sensors.\u003c\/li\u003e\n\u003cli\u003eTwinSAFE \/ FSoE Communication: Ensures secure transmission of safety data to TwinSAFE Logic devices.\u003c\/li\u003e\n\u003cli\u003eIntegrated Safety Logic: Can act as a safety controller with functionality similar to the EL6910.\u003c\/li\u003e\n\u003cli\u003eHighly Configurable Test Pulses: Fine-granular pulse configuration for all eight channels.\u003c\/li\u003e\n\u003cli\u003eHD Housing Design: Slim 12 mm terminal width for dense I\/O installations.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Compatible with standard 35 mm EN 60715 DIN rails for easy installation.\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Provides clear visual status feedback for each channel.\u003c\/li\u003e\n\u003cli\u003eService-Friendly Parameter Handling: Safety parameters are stored externally, allowing quick terminal replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EL1918 delivers the reliability and precision required for advanced machine safety and secure EtherCAT-based automation.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":47226734084394,"sku":"EL1918","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_1b0296e4-c375-4127-b17c-0a049416fe90.webp?v=1772031937","url":"https:\/\/iqelectro.com\/products\/beckhoff-el1918-safety-input-terminal-2-year-warranty","provider":"IQElectro","version":"1.0","type":"link"}