{"product_id":"c20s-150103a12-sick-c2000-standard-safety-light-curtain-1500-mm","title":"C20S-150103A12 | SICK C2000 Standard Safety Light Curtain 1500 mm","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"85\" data-end=\"376\"\u003eThe SICK C20S-150103A12 is a Type 2 safety light curtain designed to provide non-contact personnel protection for hazardous machine areas. It features a 30 mm resolution with a 1500 mm protective field height and supports reliable detection across a defined scanning range. This safety light curtain is commonly used in industrial machinery and automated production environments requiring compliant access protection.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 597.814px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eSICK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eMachine Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eC20S-150103A12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eSafety Light Curtains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eC2000 Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective Field Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e1500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eScanning Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e0 to 6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eOptical synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eType 2 (IEC 61496-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eSIL 1 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003ePL c (EN ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eCategory 2 (EN ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003ePFHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e2.2 × 10⁻⁸\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eMission Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput State on Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eAt least one OSSD OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eConfiguration Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eHard wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eBeam Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eUncoded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eM12 male connector, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e≤ 15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eIII (EN 50178)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 10px;\"\u003e\u003cstrong\u003eHousing Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 10px;\"\u003e48 × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e0 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e−25 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eAir Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e15% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e5 g, 10–55 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e10 g, 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003e950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.7154%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.0653%; height: 19.5938px;\"\u003eApprox. 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e C20S-150103A12\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe C20S-150103A12 is part of SICK’s C2000 Standard safety light curtain series, engineered for dependable machine safeguarding in medium-risk applications. It uses optical synchronization and hard-wired configuration to ensure stable and predictable safety performance. The device meets international safety standards including IEC 61496-1 Type 2 and achieves SIL 1 and PL c ratings for functional safety. Its robust housing, status indicators, and standardized M12 connection support straightforward integration into industrial control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 mm Resolution: Provides reliable detection for hand and body protection applications.\u003c\/li\u003e\n\u003cli\u003e1500 mm Protective Field Height: Covers large vertical access openings on machinery.\u003c\/li\u003e\n\u003cli\u003eScanning Range up to 6 m: Supports flexible installation distances.\u003c\/li\u003e\n\u003cli\u003eType 2 Safety Classification: Complies with IEC 61496-1 for machine safeguarding.\u003c\/li\u003e\n\u003cli\u003eSIL 1 \/ PL c Safety Ratings: Suitable for Category 2 safety architectures.\u003c\/li\u003e\n\u003cli\u003eOptical Synchronization: Ensures stable operation without electrical synchronization wiring.\u003c\/li\u003e\n\u003cli\u003eIntegrated Status Display: Includes 7-segment display and LEDs for diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe C20S-150103A12 delivers the reliability and precision required for non-contact machine safeguarding in industrial automation systems.\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":51074323382570,"sku":"C20S-150103A12","price":3299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l960_1a999355-b9e7-4317-9c58-fbec5fc29f23.webp?v=1769094276","url":"https:\/\/iqelectro.com\/products\/c20s-150103a12-sick-c2000-standard-safety-light-curtain-1500-mm","provider":"IQElectro","version":"1.0","type":"link"}