{"product_id":"c20s-180104a12-sick-c2000-standard-safety-light-curtain-1800-mm","title":"C20S-180104A12 | SICK C2000 Standard Safety Light Curtain 1800 mm","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"85\" data-end=\"376\"\u003eThe SICK C20S-180104A12 is a Type 2 safety light curtain designed to provide non-contact protection for hazardous machine areas in industrial environments. It features a 40 mm resolution with a 1800 mm protective field height to ensure reliable detection across wide access points. This safety light curtain is commonly used in machinery safeguarding and automated production systems requiring compliant personnel protection.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 607.408px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eSICK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eMachine Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eC20S-180104A12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eSafety Light Curtains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eC2000 Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective Field Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e1800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eScanning Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e0 to 6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eOptical synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eType 2 (IEC 61496-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eSIL 1 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003ePL c (EN ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eCategory 2 (EN ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003ePFHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e2.2 × 10⁻⁸\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eMission Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eBeam Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eUncoded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput State on Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eAt least one OSSD OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eConfiguration Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eHard wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eM12 male connector, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e≤ 15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eIII (EN 50178)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eHousing Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e48 × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e0 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e−25 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eAir Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e15% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e5 g, 10–55 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e10 g, 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003e950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.3093%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.4714%; height: 19.5938px;\"\u003eApprox. 1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e C20S-180104A12\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe C20S-180104A12 is part of SICK’s C2000 Standard safety light curtain series, engineered for dependable performance in medium-risk machine safety applications. It uses optical synchronization and a hard-wired configuration method to maintain stable and predictable operation. The device complies with IEC and EN safety standards, achieving SIL 1 and PL c ratings for functional safety. Its robust mechanical design, clear status indicators, and standardized M12 connectivity support reliable integration into industrial control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e40 mm Resolution: Suitable for reliable hand and body detection in machine guarding applications.\u003c\/li\u003e\n\u003cli\u003e1800 mm Protective Field Height: Covers large vertical access openings on industrial machinery.\u003c\/li\u003e\n\u003cli\u003eScanning Range up to 6 m: Allows flexible installation distances in safety layouts.\u003c\/li\u003e\n\u003cli\u003eType 2 Safety Classification: Complies with IEC 61496-1 for machine safeguarding.\u003c\/li\u003e\n\u003cli\u003eSIL 1 \/ PL c Compliance: Designed for Category 2 safety architectures.\u003c\/li\u003e\n\u003cli\u003eOptical Synchronization: Enables stable operation without electrical sync wiring.\u003c\/li\u003e\n\u003cli\u003eIntegrated Status Indication: Features 7-segment display and LEDs for diagnostics and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe C20S-180104A12 delivers the reliability and precision required for non-contact machine safeguarding in industrial automation systems.\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":51074431156522,"sku":"C20S-180104A12","price":4177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/05_12_2024_15_42_53_1016618_Sick_C20S_180104A12.png?v=1769097429","url":"https:\/\/iqelectro.com\/products\/c20s-180104a12-sick-c2000-standard-safety-light-curtain-1800-mm","provider":"IQElectro","version":"1.0","type":"link"}