{"product_id":"carrier-hk42fz062-furnace-control-circuit-board","title":"Carrier HK42FZ062 Furnace Control Circuit Board","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eCarrier HK42FZ062 is a furnace control circuit board designed to manage ignition, blower operation, thermostat inputs, and safety-related control functions in compatible HVAC systems. It is associated with the CEPL131004-20 control board and is used in compatible Carrier, Bryant, and related furnace applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 99.941%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eCarrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eHK42FZ062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eFurnace Control Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eFurnace Control Circuit Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eAssociated Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eCEPL131004-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eGas Furnace Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eHot Surface Ignition (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eIgnitor Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eHeating Stages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eCooling Stages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eMotor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003ePSC Inducer and Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eThermostat Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eR, C, W, Y, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eBlower Speed Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eLo Heat\/Fan, Hi Heat, Cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eCorded Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eFlush Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eCarrier, Bryant, Payne, ICP, Heil, Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.0221%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.5589%; height: 19.5938px;\"\u003eApproximately 1 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About HK42FZ062\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe HK42FZ062 is a Carrier furnace control board associated with the CEPL131004-20 part number and compatible control-board family. It is intended for integration into specific residential and light-commercial furnace configurations using electronic ignition and PSC blower or inducer motors. The board processes thermostat demands and coordinates heating, cooling, blower, and ignition sequences according to the connected furnace configuration. Its control architecture incorporates dedicated terminals and electronic monitoring functions for system operation and safety control.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eControl Function: Coordinates furnace ignition, blower operation, thermostat commands, and system control sequences.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePart Number Cross-Reference: Associated with Carrier\/ICP CEPL131004-20 control board assemblies.\u003c\/li\u003e\n\u003cli\u003eIgnition Type: Designed for furnace applications using hot-surface ignition.\u003c\/li\u003e\n\u003cli\u003eMotor Compatibility: Supports PSC-style inducer and blower motor configurations.\u003c\/li\u003e\n\u003cli\u003eThermostat Inputs: Provides connections for R, C, W, Y, and G thermostat control signals.\u003c\/li\u003e\n\u003cli\u003eHeating Control: Supports single-stage heating operation in compatible furnace systems.\u003c\/li\u003e\n\u003cli\u003eBlower Control: Provides separate blower-speed control connections for heating and cooling operation.\u003c\/li\u003e\n\u003cli\u003eInstallation: Designed as a direct replacement control board for compatible furnace assemblies.                                                                                                                   The HK42FZ062 delivers the reliability and precision required for furnace control, ignition sequencing, blower management, and HVAC system operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":52441908511018,"sku":"HK42FZ062","price":382.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_5f79beac-f4c2-4ffc-9621-3f72489f5054.webp?v=1788183014","url":"https:\/\/iqelectro.com\/products\/carrier-hk42fz062-furnace-control-circuit-board","provider":"IQElectro","version":"1.0","type":"link"}