{"product_id":"carrier-opn-upc-protocol-converter-module-quick-delivery","title":"OPN-UPC | Carrier Universal Protocol Converter BACnet CCN Controller Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"438\" data-start=\"101\"\u003eThe Carrier OPN-UPC is a universal protocol converter designed to integrate Carrier equipment with BACnet building automation systems. This module enables communication between CCN controllers and third-party BAS platforms, providing stable data exchange and simplified system connectivity.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eCarrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eHVAC Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eOPN-UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eProtocol Converter Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eCR2032 backup battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 39.2px;\"\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 39.2px;\"\u003eBACnet, Carrier CCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eChillers, packaged outdoor units, rooftop units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eController Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eUniversal protocol converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eFactory Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eInstalled on rooftops, air-cooled chillers, water-cooled chillers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003ePlug-and-play with Carrier i-Vu systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eBuilt-in diagnostics, trends, alarms, demand limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003eCarrier communicating space sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003e3.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003e14.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003e10.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.6106%; height: 19.6px;\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.2562%; height: 19.6px;\"\u003e1.45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eOPN-UPC\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe OPN-UPC is a Carrier universal protocol converter module engineered to provide seamless integration between Carrier CCN-based HVAC equipment and BACnet building automation systems. Designed as an easy-to-deploy communications interface, it arrives pre-programmed to share equipment data without requiring on-site engineering, simplifying installation for rooftop units, chillers, and packaged outdoor systems. The module supports Carrier communicating space sensors, offers field programmability, and includes hidden commissioning ports for convenient network setup. With built-in diagnostic graphics, trending, demand limiting, and i-Vu system compatibility, the OPN-UPC enhances equipment interoperability while improving system monitoring and control capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet and CCN Integration: Links Carrier CCN equipment to BACnet BAS platforms for unified system control.\u003c\/li\u003e\n\u003cli\u003ePre-Programmed Data Sharing: Eliminates the need for custom onsite engineering, speeding installation.\u003c\/li\u003e\n\u003cli\u003eFactory-Installed Option: Commonly used on chillers, packaged outdoor units, and rooftop systems.\u003c\/li\u003e\n\u003cli\u003eSupport for Carrier Space Sensors: Compatible with communicating sensors and offers field programming flexibility.\u003c\/li\u003e\n\u003cli\u003eHidden Commissioning Port: Provides secure and convenient network commissioning during installation.\u003c\/li\u003e\n\u003cli\u003ei-Vu Plug-and-Play Connectivity: Integrates seamlessly with Carrier’s i-Vu automation environment.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Diagnostic Tools: Includes graphics, alarm reporting, and trend data for improved troubleshooting.\u003c\/li\u003e\n\u003cli\u003eDemand Limiting Function: Helps optimize energy usage through load management strategies.\u003c\/li\u003e\n\u003cli\u003eBattery-Backed Operation: CR2032 backup battery preserves essential controller data.\u003c\/li\u003e\n\u003cli\u003eDurable Module Construction: Designed for long-term use in commercial and industrial HVAC systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe OPN-UPC delivers the reliability and precision required for advanced HVAC communication, enabling efficient integration between Carrier equipment and modern building automation platforms.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":50839374135594,"sku":"OPN-UPC","price":2029.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/opn-upc_1_highest-res_medium_8cc50251-4c4b-499a-ba2b-2931bf5fa7c0.jpg?v=1763471527","url":"https:\/\/iqelectro.com\/products\/carrier-opn-upc-protocol-converter-module-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}