{"product_id":"cerberus-pyrotronics-tri-b6-intelligent-initiating-interface-module","title":"Cerberus Pyrotronics TRI-B6 Intelligent Initiating Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Cerberus Pyrotronics TRI-B6 is an intelligent initiating interface module designed to connect dry-contact initiating devices to compatible addressable fire alarm circuits. The TRI-B6 monitors a single normally open or normally closed contact and communicates its status to Cerberus Pyrotronics MXL, XL3, or compatible IXL system circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 87.6812%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eCerberus Pyrotronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eTRI-B6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eIntelligent Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eTRI-B6 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eIntelligent Initiating Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eSingle Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eContact Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eNormally Open or Normally Closed Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eAddressing Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eProgramming Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eFPI-32 Programmer\/Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eMXL, XL3, IXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003e18 AWG minimum, 14 AWG maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003e3-1\/2 in Deep Double-Gang Switch Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eUp to 93%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eListing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8502%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.9007%; height: 19.5938px;\"\u003e10 oz (0.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eTRI-B6\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe TRI-B6 is part of the Cerberus Pyrotronics TRI-B6 Series of microcomputer-based intelligent interface modules for addressable fire alarm and security applications. It is compatible with MXL and XL3 circuits alongside IL and ID-60 Series detectors, MSI Series manual stations, and other compatible intelligent modules. The unit uses electronic addressing programmed through the FPI-32 Programmer\/Tester, eliminating mechanical DIP switches, jumpers, and rotary address controls. It is designed for installation in a 3-1\/2-inch-deep double-gang switch box and uses screw terminals for field wiring to the addressable circuit and monitored contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Contact Input: Monitors one normally open or normally closed dry-contact initiating device.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent Addressing: Uses an integrated microcomputer to store identification and operating-status information.\u003c\/li\u003e\n\u003cli\u003eElectronic Programming: Address configuration is performed with the FPI-32 Programmer\/Tester without mechanical address switches.\u003c\/li\u003e\n\u003cli\u003eAddressable Communication: Provides bidirectional communication and supervision between the interface and compatible control panel.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Supports compatible Cerberus Pyrotronics MXL, XL3, and IXL addressable system applications.\u003c\/li\u003e\n\u003cli\u003eDry-Contact Monitoring: Interfaces direct shorting devices such as fire detection and compatible security contacts with the addressable loop.\u003c\/li\u003e\n\u003cli\u003eScrew-Terminal Connections: Provides field-accessible terminals for connection to the addressable circuit and monitored wiring.\u003c\/li\u003e\n\u003cli\u003eUL Listed Design: The TRI-B6 Series intelligent interface modules are UL listed for their specified applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TRI-B6 delivers the reliability and precision required for supervised dry-contact monitoring within compatible addressable fire alarm and security systems.\u003c\/p\u003e","brand":"Cerberus Pyrotronics","offers":[{"title":"Default Title","offer_id":52257286291754,"sku":"TRI-B6","price":485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_898436ee-c54d-4979-a906-eac0365d84d2.webp?v=1786641336","url":"https:\/\/iqelectro.com\/products\/cerberus-pyrotronics-tri-b6-intelligent-initiating-interface-module","provider":"IQElectro","version":"1.0","type":"link"}