{"product_id":"chemetron-fire-systems-70101533-micro-xlt-fire-alarm-and-suppression-control-unit-nema-1","title":"Chemetron Fire Systems 70101533 Micro XLT Fire Alarm and Suppression Control Unit NEMA 1","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Chemetron Fire Systems 70101533 is a Micro XLT fire alarm and suppression control unit engineered for single-hazard fire protection applications in commercial and industrial facilities. It combines advanced microprocessor-based control with programmable releasing functions, detection circuits, and notification capabilities for dependable life-safety system management. Designed for high reliability, the control unit integrates seamlessly with clean agent, CO₂, foam, and pre-action fire suppression systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChemetron Fire Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70101533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicro XLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm and Suppression Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/220 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 VDC, 5.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Class A\/Class B configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervisory Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Class A\/Class B configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 programmable Class A\/Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReleasing Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independently programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Form-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlphanumeric display with diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClean agent, CO₂, foam, pre-action, sprinkler supervisory systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.3 kgs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan\u003e70101533\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 70101533 is a Micro XLT suppression-fire alarm control panel manufactured by Chemetron Fire Systems for advanced fire detection and suppression control. It is supplied as a NEMA 1 Control Panel Assembly operating from a 120\/220 VAC, 50\/60 Hz power source and incorporates a high-capacity microprocessor with extensive programmable logic. The controller supports multiple detection, supervisory, notification, and releasing circuits, making it suitable for clean agent, carbon dioxide, foam-water, sprinkler supervisory, and pre-action systems. Built-in diagnostics, an alphanumeric display, programmable relays, and comprehensive system monitoring provide dependable operation for critical life-safety installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-Based Control: Provides intelligent fire detection, suppression, and system management.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNEMA 1 Enclosure: Designed for indoor commercial and industrial installations.\u003c\/li\u003e\n\u003cli\u003eProgrammable Releasing Logic: Supports configurable suppression sequences for multiple hazard types.\u003c\/li\u003e\n\u003cli\u003eMultiple Detection Circuits: Includes configurable Class A or Class B detection and supervisory circuits.\u003c\/li\u003e\n\u003cli\u003eIntegrated Diagnostics: Displays battery status, charging current, countdown timers, and system events.\u003c\/li\u003e\n\u003cli\u003eFlexible Notification Outputs: Supports programmable notification appliance and releasing circuits.\u003c\/li\u003e\n\u003cli\u003eHigh-Capacity Power Supply: Delivers up to 5.4 A at 27 VDC for connected devices.\u003c\/li\u003e\n\u003cli\u003eFire Suppression Compatibility: Suitable for FM-200®, Novec™ 1230, Argonite®, CO₂, foam, and pre-action systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 70101533 delivers the reliability and precision required for advanced fire alarm and suppression control applications.\u003c\/p\u003e","brand":"Chemetron Fire Systems","offers":[{"title":"Default Title","offer_id":52199633617194,"sku":"70101533","price":2595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/medium_af21cc91-8335-40fa-9f96-cecf8ec183cd.jpg?v=1786184763","url":"https:\/\/iqelectro.com\/products\/chemetron-fire-systems-70101533-micro-xlt-fire-alarm-and-suppression-control-unit-nema-1","provider":"IQElectro","version":"1.0","type":"link"}