{"product_id":"cleaver-brooks-833-03517-burner-controller-ships-fast","title":"833-03517 | Cleaver-Brooks RM7800 L1095 Burner Programming Controller 120VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"18\" data-end=\"484\"\u003eThe Cleaver-Brooks 833-03517 is an RM7800 L1095 automatic burner programming control designed for industrial combustion systems. Operating at 120 VAC, 50\/60 Hz, it provides a 10-second pilot limit and 15-second pilot\/MV2 timing sequence for controlled burner start-up. The 833-03517 includes a keyboard display interface for status indication and diagnostics in burner management applications.\u003c\/p\u003e\n\u003ch3 data-start=\"486\" data-end=\"509\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCleaver-Brooks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e833-03517\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM7800 L1095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot\/MV2 Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Programming Burner Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Keyboard Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoiler and industrial burner systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 833-03517\u003c\/h4\u003e\n\u003cp\u003eThe 833-03517 is a Cleaver-Brooks burner control module based on the RM7800 series platform, engineered for automatic sequencing and flame safeguard control. It manages pilot and main valve timing sequences while monitoring system status and lockout conditions. The integrated keyboard display enables local viewing of operational data and diagnostic information for maintenance and troubleshooting. Designed for HVAC and boiler combustion systems, it supports reliable control of single-burner applications requiring programmable flame supervision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Programming Control: Manages burner start-up, pilot, and main valve sequencing.\u003c\/li\u003e\n\u003cli\u003e120 VAC Operation: Rated for 120 VAC input at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e10-Second Pilot Limit: Configured pilot trial-for-ignition timing.\u003c\/li\u003e\n\u003cli\u003e15-Second Pilot\/MV2 Timing: Controls second-stage pilot or main valve timing sequence.\u003c\/li\u003e\n\u003cli\u003eIntegrated Keyboard Display: Provides local system status, diagnostics, and configuration interface.\u003c\/li\u003e\n\u003cli\u003eFlame Safeguard Functionality: Monitors and supervises burner flame conditions.\u003c\/li\u003e\n\u003cli\u003eLockout Protection: Protects system by shutting down upon unsafe operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 833-03517 delivers the reliability and precision required for industrial burner control and flame safeguard applications.\u003c\/p\u003e","brand":"Cleaver-Brooks","offers":[{"title":"Default Title","offer_id":51206223954218,"sku":"833-03517","price":3954.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_1560d13d-8873-4b48-8189-e6f86e29ebed.webp?v=1772561240","url":"https:\/\/iqelectro.com\/products\/cleaver-brooks-833-03517-burner-controller-ships-fast","provider":"IQElectro","version":"1.0","type":"link"}