{"product_id":"crowcon-irmax-aa-ac-011-ac-00-fixed-infrared-hydrocarbon-gas-detector","title":"Crowcon IRMAX-AA-AC-011-AC-00 Fixed Infrared Hydrocarbon Gas Detector","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Crowcon IRMAX-AA-AC-011-AC-00 is an infrared hydrocarbon gas detector designed for fixed installation in industrial environments where continuous gas monitoring is required. The IRmax platform uses dual-beam infrared sensing, a 4–20 mA output, and a rugged stainless-steel enclosure to support detection of flammable hydrocarbon gases in hazardous areas.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"9\" style=\"width: 81.6761%; height: 426.901px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22.425px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.425px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eCrowcon\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.425px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eGas Detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.425px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eIRMAX-AA-AC-011-AC-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eInfrared Gas Detectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.425px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eIRmax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eFixed Infrared Hydrocarbon Gas Detector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDetection Technology\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eDual-beam infrared\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.8px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTarget Gas\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eHydrocarbon gases; exact calibration gas must be verified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e0–100% LEL, depending on calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e12–30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eLess than 1 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e4–20 mA current sink or source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOptional Communications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eRS-485 Modbus, HART 7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eIP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e316 stainless steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e−40°C to +75°C, subject to configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eT90 less than 4 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eFunctional Safety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003eSIL 2 system suitability, subject to applicable certification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e158 × 75 × 57 mm (detector body; configuration may vary)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2711%;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.4107%;\"\u003e\u003cspan\u003e3.5 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About IRMAX-AA-AC-011-AC-00\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe IRMAX-AA-AC-011-AC-00 belongs to Crowcon’s IRmax series of fixed-point infrared gas detectors. Its optical sensing system measures hydrocarbon gas concentrations without relying on catalytic combustion, making it suitable for applications where conventional catalytic sensors may be less appropriate. The detector supports 12–30 V DC power and a standard 4–20 mA current-loop output for connection to compatible gas monitoring and control systems. Its 316 stainless-steel enclosure and IP66 protection rating support use in demanding industrial and offshore environments.\u003cbr\u003e\u003c\/p\u003e\n\u003col start=\"3\" data-path-to-node=\"4\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eetection \u003c\/span\u003e\u003cspan\u003eTechnology: \u003c\/span\u003e\u003cspan\u003eDual-beam \u003c\/span\u003e\u003cspan\u003einfrared \u003c\/span\u003e\u003cspan\u003esensing \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ehydrocarbon \u003c\/span\u003e\u003cspan\u003egas \u003c\/span\u003e\u003cspan\u003edetection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement \u003c\/span\u003e\u003cspan\u003eRange: \u003c\/span\u003e\u003cspan\u003e0–100% \u003c\/span\u003e\u003cspan\u003eLEL, \u003c\/span\u003e\u003cspan\u003edepending \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003etarget \u003c\/span\u003e\u003cspan\u003egas \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ecalibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePower \u003c\/span\u003e\u003cspan\u003eSupply: \u003c\/span\u003e\u003cspan\u003eOperates \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003e12–30 \u003c\/span\u003e\u003cspan\u003eV \u003c\/span\u003e\u003cspan\u003eDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectrical \u003c\/span\u003e\u003cspan\u003eOutput: \u003c\/span\u003e\u003cspan\u003e4–20 \u003c\/span\u003e\u003cspan\u003emA \u003c\/span\u003e\u003cspan\u003ecurrent \u003c\/span\u003e\u003cspan\u003esink \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003esource \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eintegration \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLow \u003c\/span\u003e\u003cspan\u003ePower \u003c\/span\u003e\u003cspan\u003eConsumption: \u003c\/span\u003e\u003cspan\u003eUses \u003c\/span\u003e\u003cspan\u003eless \u003c\/span\u003e\u003cspan\u003ethan \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eW \u003c\/span\u003e\u003cspan\u003eduring \u003c\/span\u003e\u003cspan\u003enormal \u003c\/span\u003e\u003cspan\u003eoperation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eEnclosure \u003c\/span\u003e\u003cspan\u003eProtection: \u003c\/span\u003e\u003cspan\u003eIP66-rated \u003c\/span\u003e\u003cspan\u003econstruction \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003e316 \u003c\/span\u003e\u003cspan\u003estainless-steel \u003c\/span\u003e\u003cspan\u003eenclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHazardous \u003c\/span\u003e\u003cspan\u003eArea \u003c\/span\u003e\u003cspan\u003eCertification: \u003c\/span\u003e\u003cspan\u003eIRmax \u003c\/span\u003e\u003cspan\u003econfigurations \u003c\/span\u003e\u003cspan\u003eare \u003c\/span\u003e\u003cspan\u003ecertified \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003edesignated \u003c\/span\u003e\u003cspan\u003ehazardous \u003c\/span\u003e\u003cspan\u003eareas, \u003c\/span\u003e\u003cspan\u003esubject \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003eexact \u003c\/span\u003e\u003cspan\u003emodel \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ecertification \u003c\/span\u003e\u003cspan\u003elabel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOperating \u003c\/span\u003e\u003cspan\u003eTemperature: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eambient \u003c\/span\u003e\u003cspan\u003etemperatures \u003c\/span\u003e\u003cspan\u003efrom \u003c\/span\u003e\u003cspan\u003e−40°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+75°C, \u003c\/span\u003e\u003cspan\u003esubject \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003econfiguration \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ecertification \u003c\/span\u003e\u003cspan\u003elimits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eIRMAX-AA-AC-011-AC-00 \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003emonitoring \u003c\/span\u003e\u003cspan\u003ecapabilities \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003efixed \u003c\/span\u003e\u003cspan\u003ehydrocarbon \u003c\/span\u003e\u003cspan\u003egas \u003c\/span\u003e\u003cspan\u003edetection \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ehazardous-area \u003c\/span\u003e\u003cspan\u003einstallations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Crowcon","offers":[{"title":"Default Title","offer_id":52931170304298,"sku":"IRMAX-AA-AC-011-AC-00","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/LtdNIWTrdJnxdTbAV5LoYgS3XN3MDtAPw7DVD2kJjrCfc8CvYGqJZgGrAB-Rih87GuD9zXuoMdxplNlj7_y7X1NflaamYYzM614hRSm94AzJAc6wres4JnVrI6wHtoEkCIpWeUC1_oIHIEbroecFNpD51rr4hpVAJESSXdsimpw.jpg?v=1791927022","url":"https:\/\/iqelectro.com\/products\/crowcon-irmax-aa-ac-011-ac-00-fixed-infrared-hydrocarbon-gas-detector","provider":"IQElectro","version":"1.0","type":"link"}