{"product_id":"cutler-hammer-hmcp150u4cbp10-series-c-motor-circuit-protector-with-adjustable-magnetic-trip","title":"Cutler Hammer HMCP150U4CBP10 Series C Motor Circuit Protector with Adjustable Magnetic Trip","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Cutler Hammer HMCP150U4CBP10 is a 150 A, three-pole motor circuit protector for short-circuit protection in compatible combination motor starters. Its adjustable magnetic trip range of 750–2500 A supports coordination with motor starting current, with maximum voltage ratings of 600 VAC and 250 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 87.5731%; height: 362.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eCutler Hammer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eMotor Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eHMCP150U4CBP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eMotor Circuit Protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eSeries C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eMolded case motor circuit protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum AC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 10px;\"\u003e\u003cstrong\u003eMaximum DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 10px;\"\u003e250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eMagnetic-only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eMagnetic Trip Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003e750–2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eAdjustable magnetic pickup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eAssociated Starter Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eNEMA Size 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eThermal Overload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003eProvided separately by compatible starter equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.7209%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8299%; height: 19.5938px;\"\u003e4.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eHMCP150U4CBP10\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe HMCP150U4CBP10 is part of the Series C HMCP motor circuit protector range. Its molded case contains a three-pole switching mechanism with adjustable instantaneous magnetic protection. The HMCP150U4 configuration is associated with NEMA Size 4 starter applications. This magnetic-only device operates with a compatible starter and separate overload protection rather than providing thermal overload protection itself.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e150 A Current Rating: Provides the continuous current rating specified for this motor circuit protector.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable Magnetic Trip: Offers a 750–2500 A instantaneous trip adjustment range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShort-Circuit Protection: Initiates tripping when current reaches the selected magnetic threshold.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThree-Pole Construction: Switches the three power conductors in a compatible motor circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAC and DC Ratings: Supports applications up to 600 VAC or 250 VDC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStarter Coordination: Intended for compatible NEMA Size 4 combination starter applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMolded Case Design: Houses the switching and magnetic trip mechanisms in an insulating enclosure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeparate Overload Protection: Requires coordinated motor overload protection within the starter assembly.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe HMCP150U4CBP10 delivers the reliability and precision required for coordinated short-circuit protection in industrial motor starter circuits.\u003c\/span\u003e\u003c\/p\u003e","brand":"Cutler Hammer","offers":[{"title":"Default Title","offer_id":53454405828906,"sku":"HMCP150U4CBP10","price":1652.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_ae707830-8dae-4406-8813-b1508329d20e.webp?v=1793811518","url":"https:\/\/iqelectro.com\/products\/cutler-hammer-hmcp150u4cbp10-series-c-motor-circuit-protector-with-adjustable-magnetic-trip","provider":"IQElectro","version":"1.0","type":"link"}