{"product_id":"danfoss-027b1100-cvp-low-pressure-constant-pressure-pilot-valve-for-refrigeration-main-valve-control","title":"Danfoss 027B1100 CVP Low-Pressure Constant-Pressure Pilot Valve for Refrigeration Main Valve Control","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Danfoss 027B1100 is a CVP low-pressure pilot valve that regulates pressure through a compatible pilot-operated main valve in industrial refrigeration systems. Its adjustable 0–7 bar pressure range supports constant-pressure control, with a maximum working pressure of 17 bar.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 82.6023%; height: 383.73px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eRefrigeration Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003e027B1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003ePressure Pilot Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eCVP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eValve Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eCVP (LP), low pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eConstant-pressure regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003eMechanical pressure regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003ePressure Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003e0–7 bar gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003e17 bar gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 19.5938px;\"\u003e\u003cstrong\u003eKv Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 19.5938px;\"\u003e0.40 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.8542px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 35.8542px;\"\u003e\u003cstrong\u003eCv Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 35.8542px;\"\u003e0.460 US gpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 39.1875px;\"\u003e−50°C to +120°C (−58°F to +248°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.8542px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 35.8542px;\"\u003e\u003cstrong\u003eCompatible Main Valves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 35.8542px;\"\u003eCompatible Danfoss ICS and PM configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.8542px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 22.8542px;\"\u003e\u003cstrong\u003eFluid Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 22.8542px;\"\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.8542px;\"\u003e\n\u003ctd style=\"width: 36.2723%; height: 14.8542px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4318%; height: 14.8542px;\"\u003e0.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003e027B1100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe 027B1100 is a mechanically operated pressure-regulating pilot from the Danfoss CVP series. Its low-pressure configuration provides an adjustable pressure setting without an electrical actuator. It is designed for use with compatible Danfoss ICS and PM pilot-operated main valves. In these assemblies, the pilot governs main-valve operation to maintain the selected system pressure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eConstant-Pressure Regulation: Controls a compatible main valve to maintain the selected pressure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-Pressure Configuration: Provides a pressure adjustment range of 0–7 bar gauge.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMechanical Operation: Regulates pressure without requiring a solenoid coil or electrical control signal.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMain Valve Compatibility: Designed for compatible Danfoss ICS and PM pilot-operated main valves.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWorking Pressure Limit: Supports a maximum working pressure of 17 bar gauge.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDefined Flow Capacity: Provides a Kv value of 0.40 m³\/h and a Cv value of 0.460 US gpm.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature Range: Accommodates operating temperatures from −50°C to +120°C.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 027B1100 delivers the reliability and precision required for constant-pressure regulation in compatible industrial refrigeration valve assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53484771934506,"sku":"027B1100","price":795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_540e9a7d-c055-4990-984f-10caa37ca43e.webp?v=1793985398","url":"https:\/\/iqelectro.com\/products\/danfoss-027b1100-cvp-low-pressure-constant-pressure-pilot-valve-for-refrigeration-main-valve-control","provider":"IQElectro","version":"1.0","type":"link"}