{"product_id":"danfoss-034n0084-cpce-22-hot-gas-bypass-pressure-regulator-7-8-inch-odf-0-85-psi","title":"Danfoss 034N0084 CPCE 22 Hot Gas Bypass Pressure Regulator 7\/8 Inch ODF 0-85 PSI","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Danfoss 034N0084 is a hot gas bypass regulator designed to maintain stable evaporator pressure and prevent excessively low suction pressure in refrigeration and air conditioning systems operating under reduced cooling loads. Featuring a 7\/8-inch connection, it regulates the flow of hot discharge gas into the low-pressure side of a compatible refrigeration circuit. Its pressure-responsive mechanical operation helps stabilize system performance and reduce the risk of evaporator icing during low-load conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNew\/Never \u003c\/span\u003e\u003cspan\u003eUsed \u003c\/span\u003e\u003cspan\u003eSurplus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRefrigeration \u003c\/span\u003e\u003cspan\u003e\u0026amp; \u003c\/span\u003e\u003cspan\u003eHVAC \u003c\/span\u003e\u003cspan\u003eControls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e034N0084\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHot \u003c\/span\u003e\u003cspan\u003eGas \u003c\/span\u003e\u003cspan\u003eBypass \u003c\/span\u003e\u003cspan\u003eRegulators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCPCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCPCE \u003c\/span\u003e\u003cspan\u003e22\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHot \u003c\/span\u003e\u003cspan\u003eGas \u003c\/span\u003e\u003cspan\u003eBypass \u003c\/span\u003e\u003cspan\u003ePressure \u003c\/span\u003e\u003cspan\u003eRegulator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePressure-Operated \u003c\/span\u003e\u003cspan\u003eCapacity \u003c\/span\u003e\u003cspan\u003eRegulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRegulation Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0–6 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(0–85 \u003c\/span\u003e\u003cspan\u003epsig)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Pressure Setting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.4 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(5.8 \u003c\/span\u003e\u003cspan\u003epsig)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Working Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e28 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(406 \u003c\/span\u003e\u003cspan\u003epsig)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Differential Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e18 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(260 \u003c\/span\u003e\u003cspan\u003epsi)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Test Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e31 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(450 \u003c\/span\u003e\u003cspan\u003epsig)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eInlet Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e7\/8 \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003e(22 \u003c\/span\u003e\u003cspan\u003emm), \u003c\/span\u003e\u003cspan\u003eODF \u003c\/span\u003e\u003cspan\u003eSolder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOutlet Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e7\/8 \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003e(22 \u003c\/span\u003e\u003cspan\u003emm), \u003c\/span\u003e\u003cspan\u003eODF \u003c\/span\u003e\u003cspan\u003eSolder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePilot Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1\/4 \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003eFlare\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMedia Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e-50°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+140°C \u003c\/span\u003e\u003cspan\u003e(-58°F \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+284°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Capacity with R22\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e34.0 \u003c\/span\u003e\u003cspan\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Capacity with R134a\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e15.2 \u003c\/span\u003e\u003cspan\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Capacity with R404A\/R507\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e32.0 \u003c\/span\u003e\u003cspan\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Capacity with R407C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e37.1 \u003c\/span\u003e\u003cspan\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Direction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSingle \u003c\/span\u003e\u003cspan\u003eDirection, \u003c\/span\u003e\u003cspan\u003eEmbossed \u003c\/span\u003e\u003cspan\u003eArrow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLiquid-Gas Mixer Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDanfoss \u003c\/span\u003e\u003cspan\u003eLG \u003c\/span\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Power Requirement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ecULus \u003c\/span\u003e\u003cspan\u003eListed, \u003c\/span\u003e\u003cspan\u003eEAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e5702422020578\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRefrigeration \u003c\/span\u003e\u003cspan\u003eCapacity \u003c\/span\u003e\u003cspan\u003eControl, \u003c\/span\u003e\u003cspan\u003eCompressor \u003c\/span\u003e\u003cspan\u003eBypass \u003c\/span\u003e\u003cspan\u003eSystems, \u003c\/span\u003e\u003cspan\u003eEvaporator \u003c\/span\u003e\u003cspan\u003ePressure \u003c\/span\u003e\u003cspan\u003eRegulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1.87 \u003c\/span\u003e\u003cspan\u003elb\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e034N0084\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e034N0084 \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003eDanfoss \u003c\/span\u003e\u003cspan\u003emechanical \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003eregulator \u003c\/span\u003e\u003cspan\u003eintended \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ehot \u003c\/span\u003e\u003cspan\u003egas \u003c\/span\u003e\u003cspan\u003ebypass \u003c\/span\u003e\u003cspan\u003eapplications \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003ecommercial \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003eequipment. \u003c\/span\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cspan\u003evalve \u003c\/span\u003e\u003cspan\u003econstruction \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003edesigned \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003erespond \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003echanges \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003edownstream \u003c\/span\u003e\u003cspan\u003epressure, \u003c\/span\u003e\u003cspan\u003eadjusting \u003c\/span\u003e\u003cspan\u003erefrigerant \u003c\/span\u003e\u003cspan\u003ebypass \u003c\/span\u003e\u003cspan\u003eflow \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003esystem \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003econditions \u003c\/span\u003e\u003cspan\u003ewithout \u003c\/span\u003e\u003cspan\u003erequiring \u003c\/span\u003e\u003cspan\u003eexternal \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003epower. \u003c\/span\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eregulator \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003einstalled \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003eproperly \u003c\/span\u003e\u003cspan\u003edesigned \u003c\/span\u003e\u003cspan\u003ebypass \u003c\/span\u003e\u003cspan\u003eline \u003c\/span\u003e\u003cspan\u003econnecting \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ecompressor \u003c\/span\u003e\u003cspan\u003edischarge \u003c\/span\u003e\u003cspan\u003eside \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003elow-pressure \u003c\/span\u003e\u003cspan\u003eportion \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003esystem, \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003erequirements \u003c\/span\u003e\u003cspan\u003edetermined \u003c\/span\u003e\u003cspan\u003eby \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003ecircuit. \u003c\/span\u003e\u003cspan\u003eIt \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003eused \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003ecompressor \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eevaporator \u003c\/span\u003e\u003cspan\u003earrangements \u003c\/span\u003e\u003cspan\u003ewhere \u003c\/span\u003e\u003cspan\u003ecapacity \u003c\/span\u003e\u003cspan\u003ereduction, \u003c\/span\u003e\u003cspan\u003esuction \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003estabilization, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003elow-load \u003c\/span\u003e\u003cspan\u003etemperature \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eare \u003c\/span\u003e\u003cspan\u003erequired.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHot \u003c\/span\u003e\u003cspan\u003eGas \u003c\/span\u003e\u003cspan\u003eBypass \u003c\/span\u003e\u003cspan\u003eRegulation: \u003c\/span\u003e\u003cspan\u003eControls \u003c\/span\u003e\u003cspan\u003edischarge \u003c\/span\u003e\u003cspan\u003egas \u003c\/span\u003e\u003cspan\u003ebypass \u003c\/span\u003e\u003cspan\u003eflow \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003esupport \u003c\/span\u003e\u003cspan\u003estable \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003eunder \u003c\/span\u003e\u003cspan\u003ereduced \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003edemand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eEvaporator \u003c\/span\u003e\u003cspan\u003ePressure \u003c\/span\u003e\u003cspan\u003eStabilization: \u003c\/span\u003e\u003cspan\u003eHelps \u003c\/span\u003e\u003cspan\u003emaintain \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003elow-side \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003eas \u003c\/span\u003e\u003cspan\u003eevaporator \u003c\/span\u003e\u003cspan\u003eload \u003c\/span\u003e\u003cspan\u003edecreases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e7\/8-Inch \u003c\/span\u003e\u003cspan\u003eConnection: \u003c\/span\u003e\u003cspan\u003eFeatures \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003enominal \u003c\/span\u003e\u003cspan\u003e7\/8-inch \u003c\/span\u003e\u003cspan\u003econnection \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eintegration \u003c\/span\u003e\u003cspan\u003einto \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003erefrigerant \u003c\/span\u003e\u003cspan\u003epiping.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMechanical \u003c\/span\u003e\u003cspan\u003ePressure \u003c\/span\u003e\u003cspan\u003eControl: \u003c\/span\u003e\u003cspan\u003eOperates \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003erefrigerant \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003echanges \u003c\/span\u003e\u003cspan\u003ewithout \u003c\/span\u003e\u003cspan\u003ean \u003c\/span\u003e\u003cspan\u003eexternal \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003esupply.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLow-Load \u003c\/span\u003e\u003cspan\u003eOperation: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003esystems \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003ebelow \u003c\/span\u003e\u003cspan\u003etheir \u003c\/span\u003e\u003cspan\u003enormal \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003ecapacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eEvaporator \u003c\/span\u003e\u003cspan\u003eFreeze \u003c\/span\u003e\u003cspan\u003eProtection: \u003c\/span\u003e\u003cspan\u003eHelps \u003c\/span\u003e\u003cspan\u003ereduce \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003elikelihood \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eevaporator \u003c\/span\u003e\u003cspan\u003eicing \u003c\/span\u003e\u003cspan\u003ecaused \u003c\/span\u003e\u003cspan\u003eby \u003c\/span\u003e\u003cspan\u003eexcessively \u003c\/span\u003e\u003cspan\u003elow \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003epressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCompressor \u003c\/span\u003e\u003cspan\u003eOperating \u003c\/span\u003e\u003cspan\u003eStability: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003econsistent \u003c\/span\u003e\u003cspan\u003esuction-side \u003c\/span\u003e\u003cspan\u003econditions \u003c\/span\u003e\u003cspan\u003eduring \u003c\/span\u003e\u003cspan\u003echanging \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003edemand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic \u003c\/span\u003e\u003cspan\u003eValve \u003c\/span\u003e\u003cspan\u003eModulation: \u003c\/span\u003e\u003cspan\u003eAdjusts \u003c\/span\u003e\u003cspan\u003ebypass \u003c\/span\u003e\u003cspan\u003eflow \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003eresponse \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003evariations \u003c\/span\u003e\u003cspan\u003ewithin \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003ecircuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eRefrigeration \u003c\/span\u003e\u003cspan\u003eSystem \u003c\/span\u003e\u003cspan\u003eIntegration: \u003c\/span\u003e\u003cspan\u003eSuitable \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003ecommercial \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eair \u003c\/span\u003e\u003cspan\u003econditioning \u003c\/span\u003e\u003cspan\u003einstallations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial \u003c\/span\u003e\u003cspan\u003eValve \u003c\/span\u003e\u003cspan\u003eConstruction: \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003epressurized \u003c\/span\u003e\u003cspan\u003erefrigerant \u003c\/span\u003e\u003cspan\u003ecircuits \u003c\/span\u003e\u003cspan\u003eusing \u003c\/span\u003e\u003cspan\u003eappropriate \u003c\/span\u003e\u003cspan\u003econnection \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003esealing \u003c\/span\u003e\u003cspan\u003eprocedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e034N0084 \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ereliability \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprecision \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ehot \u003c\/span\u003e\u003cspan\u003egas \u003c\/span\u003e\u003cspan\u003ebypass \u003c\/span\u003e\u003cspan\u003eregulation, \u003c\/span\u003e\u003cspan\u003eevaporator \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003estabilization, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003erefrigeration \u003c\/span\u003e\u003cspan\u003ecapacity \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eduring \u003c\/span\u003e\u003cspan\u003evariable \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003eloads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53366482272554,"sku":"034N0084","price":675.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_694f9b35-350f-430a-9514-a2d392f56948.webp?v=1793214849","url":"https:\/\/iqelectro.com\/products\/danfoss-034n0084-cpce-22-hot-gas-bypass-pressure-regulator-7-8-inch-odf-0-85-psi","provider":"IQElectro","version":"1.0","type":"link"}