{"product_id":"danfoss-11162991-fdca-12v-hydraulic-fan-drive-control-valve-assembly-normally-closed","title":"Danfoss 11162991 FDCA 12V Hydraulic Fan Drive Control Valve Assembly Normally Closed","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Danfoss 11162991 is a 12V hydraulic fan control valve assembly designed to regulate cooling fan operation in mobile hydraulic equipment and industrial machinery. It provides hydraulic control of fan operation in response to cooling system requirements, helping manage airflow through engine and hydraulic oil cooling systems. This assembly is intended for applications using compatible Danfoss hydraulic fan drive systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNew\/Never \u003c\/span\u003e\u003cspan\u003eUsed \u003c\/span\u003e\u003cspan\u003eSurplus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHydraulics \u003c\/span\u003e\u003cspan\u003e\u0026amp; \u003c\/span\u003e\u003cspan\u003eFluid \u003c\/span\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e11162991\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eFan \u003c\/span\u003e\u003cspan\u003eControl \u003c\/span\u003e\u003cspan\u003eAssemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFDCA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eElectronic \u003c\/span\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eFan \u003c\/span\u003e\u003cspan\u003eDrive \u003c\/span\u003e\u003cspan\u003eControl \u003c\/span\u003e\u003cspan\u003eAssembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Designation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFDCA \u003c\/span\u003e\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003eHCN21 \u003c\/span\u003e\u003cspan\u003ePMPM8 \u003c\/span\u003e\u003cspan\u003eHIRF3 \u003c\/span\u003e\u003cspan\u003e3000\/210 \u003c\/span\u003e\u003cspan\u003eNC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003eVDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Supply Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e9–32 \u003c\/span\u003e\u003cspan\u003eVDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eValve Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNormally \u003c\/span\u003e\u003cspan\u003eClosed \u003c\/span\u003e\u003cspan\u003e(NC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eControl Method\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eElectronic \u003c\/span\u003e\u003cspan\u003eProportional \u003c\/span\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eControl\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eControl Inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eSensors \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eAuxiliary \u003c\/span\u003e\u003cspan\u003eSwitches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMain Electrical Connector\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e8-Pin \u003c\/span\u003e\u003cspan\u003eDelphi \u003c\/span\u003e\u003cspan\u003eMetri-Pack \u003c\/span\u003e\u003cspan\u003e150 \u003c\/span\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCAN \u003c\/span\u003e\u003cspan\u003evia \u003c\/span\u003e\u003cspan\u003e3-Pin \u003c\/span\u003e\u003cspan\u003eDEUTSCH \u003c\/span\u003e\u003cspan\u003eConnector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eHydraulic Valve Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eProportional \u003c\/span\u003e\u003cspan\u003eSolenoid \u003c\/span\u003e\u003cspan\u003eCartridge \u003c\/span\u003e\u003cspan\u003eValve\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eManifold Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAluminum \u003c\/span\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eManifold\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e-40°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+105°C \u003c\/span\u003e\u003cspan\u003e(-40°F \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+221°F), \u003c\/span\u003e\u003cspan\u003eFDCA \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eRating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP67, \u003c\/span\u003e\u003cspan\u003eFDCA \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eRating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Valve Inlet Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e241.4 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(3,500 \u003c\/span\u003e\u003cspan\u003epsi), \u003c\/span\u003e\u003cspan\u003eFDCA \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eRating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Valve Outlet Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e6.9 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(100 \u003c\/span\u003e\u003cspan\u003epsi), \u003c\/span\u003e\u003cspan\u003eFDCA \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eRating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Valve Pressure Drop\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e10.3 \u003c\/span\u003e\u003cspan\u003ebar \u003c\/span\u003e\u003cspan\u003e(150 \u003c\/span\u003e\u003cspan\u003epsi) \u003c\/span\u003e\u003cspan\u003eat \u003c\/span\u003e\u003cspan\u003e0.95 \u003c\/span\u003e\u003cspan\u003eL\/min, \u003c\/span\u003e\u003cspan\u003eFDCA \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated FDC Module Part Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e11162993\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eCooling \u003c\/span\u003e\u003cspan\u003eFans, \u003c\/span\u003e\u003cspan\u003eMobile \u003c\/span\u003e\u003cspan\u003eEquipment, \u003c\/span\u003e\u003cspan\u003eEngine \u003c\/span\u003e\u003cspan\u003eCooling \u003c\/span\u003e\u003cspan\u003eSystems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.00 lb\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e11162991\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e11162991 \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003eDanfoss \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eassembly \u003c\/span\u003e\u003cspan\u003edesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eintegration \u003c\/span\u003e\u003cspan\u003einto \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003emobile \u003c\/span\u003e\u003cspan\u003eequipment \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003ecircuits. \u003c\/span\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cspan\u003eelectrically \u003c\/span\u003e\u003cspan\u003eoperated \u003c\/span\u003e\u003cspan\u003evalve \u003c\/span\u003e\u003cspan\u003econfiguration \u003c\/span\u003e\u003cspan\u003euses \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003enominal \u003c\/span\u003e\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003eVDC \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003esupply \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003emanage \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003edrive \u003c\/span\u003e\u003cspan\u003eoperation. \u003c\/span\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eassembly \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003eintended \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003emachinery \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003efans, \u003c\/span\u003e\u003cspan\u003eincluding \u003c\/span\u003e\u003cspan\u003econstruction \u003c\/span\u003e\u003cspan\u003eequipment, \u003c\/span\u003e\u003cspan\u003eagricultural \u003c\/span\u003e\u003cspan\u003emachinery, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eother \u003c\/span\u003e\u003cspan\u003emobile \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003eapplications. \u003c\/span\u003e\u003cspan\u003eProper \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003erequires \u003c\/span\u003e\u003cspan\u003ematching \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003evalve's \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003econnections, \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003epressure, \u003c\/span\u003e\u003cspan\u003eflow \u003c\/span\u003e\u003cspan\u003erequirements, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003echaracteristics \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003eoriginal \u003c\/span\u003e\u003cspan\u003eequipment \u003c\/span\u003e\u003cspan\u003econfiguration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eFan \u003c\/span\u003e\u003cspan\u003eControl: \u003c\/span\u003e\u003cspan\u003eRegulates \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003edrive \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eequipment \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e12V \u003c\/span\u003e\u003cspan\u003eElectrical \u003c\/span\u003e\u003cspan\u003eOperation: \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003enominal \u003c\/span\u003e\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003eVDC \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003esystem.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eTemperature-Related \u003c\/span\u003e\u003cspan\u003eControl: \u003c\/span\u003e\u003cspan\u003eIntended \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003eapplications \u003c\/span\u003e\u003cspan\u003ewhere \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003eadjusted \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003esystem \u003c\/span\u003e\u003cspan\u003etemperature \u003c\/span\u003e\u003cspan\u003erequirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHydraulic \u003c\/span\u003e\u003cspan\u003eValve \u003c\/span\u003e\u003cspan\u003eAssembly: \u003c\/span\u003e\u003cspan\u003eCombines \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003eactuation \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003efluid \u003c\/span\u003e\u003cspan\u003econtrol.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMobile \u003c\/span\u003e\u003cspan\u003eEquipment \u003c\/span\u003e\u003cspan\u003eApplication: \u003c\/span\u003e\u003cspan\u003eSuitable \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003econstruction, \u003c\/span\u003e\u003cspan\u003eagricultural, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eoff-highway \u003c\/span\u003e\u003cspan\u003emachinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCooling \u003c\/span\u003e\u003cspan\u003eSystem \u003c\/span\u003e\u003cspan\u003eIntegration: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003ehydraulically \u003c\/span\u003e\u003cspan\u003edriven \u003c\/span\u003e\u003cspan\u003efans \u003c\/span\u003e\u003cspan\u003eused \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eengine \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003eoil \u003c\/span\u003e\u003cspan\u003ecooling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectrical \u003c\/span\u003e\u003cspan\u003eControl \u003c\/span\u003e\u003cspan\u003eInterface: \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ereceive \u003c\/span\u003e\u003cspan\u003ecommands \u003c\/span\u003e\u003cspan\u003efrom \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecircuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eVariable \u003c\/span\u003e\u003cspan\u003eCooling \u003c\/span\u003e\u003cspan\u003eDemand: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003estrategy \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003eassociated \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003esystem.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOEM \u003c\/span\u003e\u003cspan\u003eReplacement \u003c\/span\u003e\u003cspan\u003eApplication: \u003c\/span\u003e\u003cspan\u003eIdentified \u003c\/span\u003e\u003cspan\u003eby \u003c\/span\u003e\u003cspan\u003eDanfoss \u003c\/span\u003e\u003cspan\u003epart \u003c\/span\u003e\u003cspan\u003enumber \u003c\/span\u003e\u003cspan\u003e11162991 \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ematching \u003c\/span\u003e\u003cspan\u003eexisting \u003c\/span\u003e\u003cspan\u003eequipment \u003c\/span\u003e\u003cspan\u003eassemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSystem \u003c\/span\u003e\u003cspan\u003eCompatibility: \u003c\/span\u003e\u003cspan\u003eRequires \u003c\/span\u003e\u003cspan\u003everification \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003eport \u003c\/span\u003e\u003cspan\u003econfiguration, \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003econnector, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003evalve \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003echaracteristics \u003c\/span\u003e\u003cspan\u003ebefore \u003c\/span\u003e\u003cspan\u003ereplacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e11162991 \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ereliability \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprecision \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ehydraulic \u003c\/span\u003e\u003cspan\u003ecooling \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003eregulation, \u003c\/span\u003e\u003cspan\u003ethermal \u003c\/span\u003e\u003cspan\u003emanagement, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003econtrolled \u003c\/span\u003e\u003cspan\u003efan \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003emobile \u003c\/span\u003e\u003cspan\u003emachinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53344562413866,"sku":"11162991","price":692.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_ec73dfcc-7fd2-4b72-8b79-16f891c5a023.webp?v=1793136688","url":"https:\/\/iqelectro.com\/products\/danfoss-11162991-fdca-12v-hydraulic-fan-drive-control-valve-assembly-normally-closed","provider":"IQElectro","version":"1.0","type":"link"}