{"product_id":"delta-controls-dsc-1616e-bacnet-system-controller","title":"Delta Controls DSC-1616E BACnet System Controller","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe Delta Controls DSC-1616E is a fully programmable BACnet building controller designed for HVAC and building management systems. It features 16 universal inputs and 16 configurable analog outputs that can operate as analog or binary outputs, allowing it to monitor sensors and control connected equipment. With Ethernet connectivity, BACnet\/IP, BACnet MS\/TP, and support for Delta LINKnet devices, it is suitable for applications involving air handling units, boilers, chillers, and other building systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 443px; max-width: 100%; font-size: 14px; height: 587.813px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eDelta Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eHVAC \u0026amp; Building Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eDSC-1616E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eBuilding Automation Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eController Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eProgrammable BACnet System Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eBACnet Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eBACnet Building Controller (B-BC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eUniversal Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eInput Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e10-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 130.115px;\"\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 286.885px;\"\u003e0–5 VDC, 0–10 VDC, 10 kΩ thermistor, dry contact, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 130.115px;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 286.885px;\"\u003e16 × 0–10 VDC, software-configurable as analog or binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 130.115px;\"\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 286.885px;\"\u003e20 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 130.115px;\"\u003e\u003cstrong\u003eManual Overrides\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 286.885px;\"\u003eHand-Off-Auto (HOA) switches with position feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e24 VAC, 50\/60 Hz, Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e10BASE-T, 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eNetwork Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003eBACnet\/IP, BACnet Ethernet, BACnet MS\/TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e32-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eFlash Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eRAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e512 KB SRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 130.115px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 39.1875px; width: 286.885px;\"\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e10–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 130.115px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; height: 19.5938px; width: 286.885px;\"\u003e 0.93 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About DSC-1616E\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe DSC-1616E is a Delta Controls system controller designed for installations requiring a larger number of inputs and outputs in one controller. Its 16 universal inputs support 0–5 VDC, 0–10 VDC, 10 kΩ thermistors, dry contacts, and 4–20 mA signals. The 16 outputs provide 0–10 VDC signals and can be configured in software for analog or binary operation, with individual Hand-Off-Auto (HOA) switches and position feedback. The controller supports programmable GCL+ logic, network-based firmware and application database updates, and optional Modbus RTU functionality using a compatible hardware key.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e16 Universal Inputs: Monitors a wide range of compatible sensors and field signals.\u003c\/li\u003e\n\u003cli\u003e16 Configurable Outputs: Provides 0–10 VDC outputs configurable for analog or binary operation.\u003c\/li\u003e\n\u003cli\u003eNative BACnet Support: Integrates with compatible building automation systems.\u003c\/li\u003e\n\u003cli\u003eEthernet Connectivity: Supports BACnet\/IP and BACnet over Ethernet.\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication: Supports BACnet MS\/TP networking.\u003c\/li\u003e\n\u003cli\u003eDelta LINKnet Support: Connects compatible Delta Controls field devices through the supported subnetwork.\u003c\/li\u003e\n\u003cli\u003eProgrammable GCL+ Logic: Allows application-specific control sequences.\u003c\/li\u003e\n\u003cli\u003eOptional Modbus RTU: Can be enabled with the compatible hardware key.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DSC-1616E provides centralized monitoring and programmable control for medium-sized HVAC and building automation applications.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Delta Controls","offers":[{"title":"Default Title","offer_id":52936786805034,"sku":"DSC-1616E","price":1625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/R.jpg?v=1791961433","url":"https:\/\/iqelectro.com\/products\/delta-controls-dsc-1616e-bacnet-system-controller","provider":"IQElectro","version":"1.0","type":"link"}