{"product_id":"det-tronics-010210-001-interface-module-ships-fast","title":"DET-TRONICS 010210-001 EQ3750DW Addressable Smoke and Heat Detector Interface Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"493\" data-start=\"17\"\u003eThe DET-TRONICS 010210-001 (EQ3750DW) is an addressable smoke and heat detector interface module designed for use with the Eagle Quantum Premier (EQP) fire and gas safety system. It provides reliable monitoring of conventional smoke and heat detectors through a supervised detection loop while enabling seamless communication with the EQP Local Operating Network.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 81.7029%; height: 548.326px;\" height=\"717\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eDET-TRONICS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.4125px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eFire Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003e010210-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eSmoke and Heat Detector Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eEQ3750DW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.4125px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eAddressable Smoke and Heat Detector Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.8px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eEagle Quantum Premier (EQP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003e18–30 VDC (24 VDC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003e690 mA Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eLoop Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003e225 mA Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eInput Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eTwo-Wire Class B (Style B) Supervised Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eEQP Local Operating Network (LON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eDetector Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eUp to 20 Conventional Smoke Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.8px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eDetection Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eSmoke and Heat Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.8px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eInstallation Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eIndustrial and Hazardous Locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.4125px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eEnclosure Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eExplosion-Proof or NEMA 4X Rated Enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003e–40°C to +85°C (–40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003eAddressable Fire Detection Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.8077%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9248%;\"\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e010210-001\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1240\" data-start=\"518\"\u003eThe 010210-001 is part of the Det-Tronics Eagle Quantum Premier product family, developed for advanced fire and gas detection systems used in industrial and hazardous environments. Designed as an addressable detector interface, the module connects conventional smoke and heat detectors to the EQP platform through a supervised two-wire detection loop. The unit communicates digitally over the Local Operating Network (LON), allowing centralized alarm processing, diagnostics, and event management. Its compatibility with explosion-proof and NEMA 4X enclosures makes it suitable for demanding installations requiring environmental protection and long-term reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2143\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1155\" data-end=\"1893\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1228\" data-end=\"2024\"\u003e\n\u003cli data-section-id=\"18fr116\" data-start=\"1228\" data-end=\"1328\"\u003eAddressable Detector Interface: Integrates conventional smoke and heat detectors into EQP systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1lqr9n3\" data-start=\"1329\" data-end=\"1440\"\u003eEagle Quantum Premier Compatibility: Designed specifically for Det-Tronics EQP fire and gas safety platforms.\u003c\/li\u003e\n\u003cli data-section-id=\"f27rvy\" data-start=\"1441\" data-end=\"1523\"\u003eSupervised Detection Loop: Utilizes a two-wire Class B supervised input circuit.\u003c\/li\u003e\n\u003cli data-section-id=\"u8acsg\" data-start=\"1524\" data-end=\"1626\"\u003eDigital Network Communication: Supports communication through the EQP Local Operating Network (LON).\u003c\/li\u003e\n\u003cli data-section-id=\"1uk0dg2\" data-start=\"1627\" data-end=\"1731\"\u003eMulti-Detector Support: Accommodates up to 20 conventional smoke detectors depending on detector type.\u003c\/li\u003e\n\u003cli data-section-id=\"141m4bf\" data-start=\"1732\" data-end=\"1817\"\u003eWide Operating Voltage Range: Operates from 18 to 30 VDC with 24 VDC nominal input.\u003c\/li\u003e\n\u003cli data-section-id=\"1qa83ur\" data-start=\"1818\" data-end=\"1920\"\u003eIndustrial Environmental Design: Suitable for installation in explosion-proof or NEMA 4X enclosures.\u003c\/li\u003e\n\u003cli data-section-id=\"1iac2sa\" data-start=\"1921\" data-end=\"2024\"\u003eExtended Temperature Range: Rated for operation in harsh industrial environments from –40°C to +85°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2026\" data-end=\"2154\"\u003eThe 010210-001 delivers the reliability and precision required for industrial fire detection and life-safety monitoring systems.\u003c\/p\u003e","brand":"DET TRONICS","offers":[{"title":"Default Title","offer_id":51657334915370,"sku":"010210-001","price":2495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/19_11_2025_15_49_36_010210_001_Det_Tronics_EQ3750DW.png?v=1780938329","url":"https:\/\/iqelectro.com\/products\/det-tronics-010210-001-interface-module-ships-fast","provider":"IQElectro","version":"1.0","type":"link"}