{"product_id":"eaton-ae16nn0-freedom-series-140a-3-pole-non-reversing-magnetic-motor-starter-110-120v-coil","title":"Eaton AE16NN0 Freedom Series 140A 3-Pole Non-Reversing Magnetic Motor Starter 110-120V Coil","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Eaton Cutler-Hammer AE16NN0 is a Freedom Series three-pole, non-reversing magnetic motor starter designed for controlling three-phase industrial motors and providing overload protection. Eaton part number AE16NN0 combines a 140 A contactor, a 110–120 VAC operating coil, and an overload relay assembly identified as 10-6530-3, with a reported adjustable overload range of 84–115 A. Designed for industrial motor control systems operating at up to 600 VAC, this starter supports motor switching and protection in machinery, pumps, compressors, and other heavy-duty equipment.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNew\/Never \u003c\/span\u003e\u003cspan\u003eUsed \u003c\/span\u003e\u003cspan\u003eSurplus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eEaton \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003eCutler-Hammer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial \u003c\/span\u003e\u003cspan\u003eMotor \u003c\/span\u003e\u003cspan\u003eControl\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAE16NN0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic \u003c\/span\u003e\u003cspan\u003eMotor \u003c\/span\u003e\u003cspan\u003eStarters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFreedom \u003c\/span\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNon-Reversing \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003eMagnetic \u003c\/span\u003e\u003cspan\u003eMotor \u003c\/span\u003e\u003cspan\u003eStarter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly Identification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAE16NN0 \u003c\/span\u003e\u003cspan\u003e10E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eContactor Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e3-Pole \u003c\/span\u003e\u003cspan\u003eElectromagnetic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e140 \u003c\/span\u003e\u003cspan\u003eA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Operating Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e600 \u003c\/span\u003e\u003cspan\u003eVAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eControl Coil Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e110 \u003c\/span\u003e\u003cspan\u003eVAC \u003c\/span\u003e\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eHz \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003eVAC \u003c\/span\u003e\u003cspan\u003e60 \u003c\/span\u003e\u003cspan\u003eHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThree-Phase\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Motor Horsepower\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e125 \u003c\/span\u003e\u003cspan\u003eHP \u003c\/span\u003e\u003cspan\u003eat \u003c\/span\u003e\u003cspan\u003e600 \u003c\/span\u003e\u003cspan\u003eVAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e10-6530-3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Adjustment Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e84–115 \u003c\/span\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cspan\u003e(Referenced \u003c\/span\u003e\u003cspan\u003eAssembly)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStarting Method\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFull \u003c\/span\u003e\u003cspan\u003eVoltage \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003eDirect-On-Line\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOpen-Type \u003c\/span\u003e\u003cspan\u003ePanel \u003c\/span\u003e\u003cspan\u003eMount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApprox. \u003c\/span\u003e\u003cspan\u003e30 \u003c\/span\u003e\u003cspan\u003elb \u003c\/span\u003e\u003cspan\u003e(Verify \u003c\/span\u003e\u003cspan\u003eAssembled \u003c\/span\u003e\u003cspan\u003eUnit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eAE16NN0\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eAE16NN0 \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003epart \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eEaton's \u003c\/span\u003e\u003cspan\u003eCutler-Hammer \u003c\/span\u003e\u003cspan\u003eFreedom \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eelectromagnetic \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eequipment, \u003c\/span\u003e\u003cspan\u003efeaturing \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003emodular \u003c\/span\u003e\u003cspan\u003econtactor \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003erelay \u003c\/span\u003e\u003cspan\u003earrangement \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003einstallations. \u003c\/span\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cspan\u003ethree-pole \u003c\/span\u003e\u003cspan\u003econstruction \u003c\/span\u003e\u003cspan\u003eprovides \u003c\/span\u003e\u003cspan\u003esimultaneous \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ethree-phase \u003c\/span\u003e\u003cspan\u003epower \u003c\/span\u003e\u003cspan\u003ecircuits, \u003c\/span\u003e\u003cspan\u003ewhile \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003e110–120 \u003c\/span\u003e\u003cspan\u003eVAC \u003c\/span\u003e\u003cspan\u003ecoil \u003c\/span\u003e\u003cspan\u003eallows \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003econventional \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecircuits. \u003c\/span\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eassociated \u003c\/span\u003e\u003cspan\u003e10-6530-3 \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003eassembly \u003c\/span\u003e\u003cspan\u003eprovides \u003c\/span\u003e\u003cspan\u003eadjustable \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003eprotection, \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003esetting \u003c\/span\u003e\u003cspan\u003eselected \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003econnected \u003c\/span\u003e\u003cspan\u003emotor's \u003c\/span\u003e\u003cspan\u003enameplate \u003c\/span\u003e\u003cspan\u003ecurrent \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eapplicable \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003erequirements. \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecenters, \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003epanels, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003eenclosures, \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003estarter \u003c\/span\u003e\u003cspan\u003euses \u003c\/span\u003e\u003cspan\u003efull-voltage, \u003c\/span\u003e\u003cspan\u003enon-reversing \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003esupports \u003c\/span\u003e\u003cspan\u003emaintenance \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003ereplacement \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eFreedom \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecomponents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eFreedom \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eConstruction: \u003c\/span\u003e\u003cspan\u003eEaton \u003c\/span\u003e\u003cspan\u003eCutler-Hammer \u003c\/span\u003e\u003cspan\u003eelectromagnetic \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003estarter \u003c\/span\u003e\u003cspan\u003edesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003eapplications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e140 \u003c\/span\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cspan\u003eContactor \u003c\/span\u003e\u003cspan\u003eRating: \u003c\/span\u003e\u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003ehigh-current \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003ecapability \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003ethree-phase \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003eloads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThree-Pole \u003c\/span\u003e\u003cspan\u003eConfiguration: \u003c\/span\u003e\u003cspan\u003eControls \u003c\/span\u003e\u003cspan\u003eall \u003c\/span\u003e\u003cspan\u003ethree \u003c\/span\u003e\u003cspan\u003ephases \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003ethree-phase \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003esupply.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eNon-Reversing \u003c\/span\u003e\u003cspan\u003eOperation: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003econventional \u003c\/span\u003e\u003cspan\u003eforward \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003ewithout \u003c\/span\u003e\u003cspan\u003ean \u003c\/span\u003e\u003cspan\u003eintegrated \u003c\/span\u003e\u003cspan\u003ereversing \u003c\/span\u003e\u003cspan\u003econtactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e110–120 \u003c\/span\u003e\u003cspan\u003eVAC \u003c\/span\u003e\u003cspan\u003eCoil: \u003c\/span\u003e\u003cspan\u003eElectromagnetic \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003ecoil \u003c\/span\u003e\u003cspan\u003edesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003estandard \u003c\/span\u003e\u003cspan\u003eAC \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecircuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e600 \u003c\/span\u003e\u003cspan\u003eVAC \u003c\/span\u003e\u003cspan\u003eMaximum \u003c\/span\u003e\u003cspan\u003eVoltage: \u003c\/span\u003e\u003cspan\u003eSuitable \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003einstallations \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003erated \u003c\/span\u003e\u003cspan\u003esupply \u003c\/span\u003e\u003cspan\u003evoltages \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e600 \u003c\/span\u003e\u003cspan\u003eVAC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOverload \u003c\/span\u003e\u003cspan\u003eProtection: \u003c\/span\u003e\u003cspan\u003eIncludes \u003c\/span\u003e\u003cspan\u003ean \u003c\/span\u003e\u003cspan\u003eassociated \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003erelay \u003c\/span\u003e\u003cspan\u003eassembly \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003eovercurrent \u003c\/span\u003e\u003cspan\u003eprotection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable \u003c\/span\u003e\u003cspan\u003eOverload \u003c\/span\u003e\u003cspan\u003eRange: \u003c\/span\u003e\u003cspan\u003eReported \u003c\/span\u003e\u003cspan\u003e84–115 \u003c\/span\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cspan\u003esetting \u003c\/span\u003e\u003cspan\u003erange \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003e10-6530-3 \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003eassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eFull-Voltage \u003c\/span\u003e\u003cspan\u003eStarting: \u003c\/span\u003e\u003cspan\u003eConnects \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003edirectly \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003esupply \u003c\/span\u003e\u003cspan\u003eduring \u003c\/span\u003e\u003cspan\u003enormal \u003c\/span\u003e\u003cspan\u003estarting \u003c\/span\u003e\u003cspan\u003eoperation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eModular \u003c\/span\u003e\u003cspan\u003eComponent \u003c\/span\u003e\u003cspan\u003eDesign: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eservicing \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ereplacement \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003econtactor \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003ecomponents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial \u003c\/span\u003e\u003cspan\u003ePanel \u003c\/span\u003e\u003cspan\u003eIntegration: \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003euse \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ecenters, \u003c\/span\u003e\u003cspan\u003eequipment \u003c\/span\u003e\u003cspan\u003epanels, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eAE16NN0 \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ereliability \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprecision \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ethree-phase \u003c\/span\u003e\u003cspan\u003emotor \u003c\/span\u003e\u003cspan\u003eswitching, \u003c\/span\u003e\u003cspan\u003eadjustable \u003c\/span\u003e\u003cspan\u003eoverload \u003c\/span\u003e\u003cspan\u003eprotection, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003emachinery \u003c\/span\u003e\u003cspan\u003econtrol.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":52940353274154,"sku":"AE16NN0","price":3099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_4e41bc04-fef8-4c97-8c96-995ac9e29032.jpg?v=1791999702","url":"https:\/\/iqelectro.com\/products\/eaton-ae16nn0-freedom-series-140a-3-pole-non-reversing-magnetic-motor-starter-110-120v-coil","provider":"IQElectro","version":"1.0","type":"link"}