{"product_id":"eaton-bw2175-main-circuit-breaker-secure-packaging","title":"BW2175 | Eaton 175A 2-Pole 120\/240V Plug-On Thermal Magnetic Main Circuit Breaker","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Eaton BW2175 is a 175-amp, 2-pole thermal-magnetic main circuit breaker designed for 120\/240-volt single-phase HVAC and service entrance applications. It provides Long-Time and Instantaneous protection to prevent damage from overloads and short circuits. With a 10 kA interrupting rating and plug-on mounting design, the BW2175 supports straightforward installation in residential and light commercial equipment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot Devices \u003cem\u003e(as provided)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBW2175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelector Switch \u003cem\u003e(as provided)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal \/ Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA @ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine-Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 AWG to 300 kcmil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\" W × 3.1\" D × 3.1\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 to 75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHVAC, service entrance modules, residential\/commercial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About BW2175\u003c\/h4\u003e\n\u003cp\u003eThe BW2175 is part of Eaton’s BW Series main breaker family, commonly used in service modules and HVAC power control applications. Its molded case design incorporates a fixed thermal-magnetic trip mechanism that offers dependable LI protection across connected loads. Rated at 175 amps and compatible with 120\/240-volt systems, the breaker integrates through plug-on mounting with line-side terminals for fast and secure installation. Supporting wire sizes from 2 AWG to 300 kcmil, the BW2175 is suited for heating, air-conditioning, refrigeration, and general service entrance configurations requiring reliable overcurrent protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e175A thermal-magnetic protection: Suitable for HVAC and service entrance circuits.\u003c\/li\u003e\n\u003cli\u003e2-pole construction: Supports 120\/240-V single-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting: Enables quick installation in compatible load centers or panels.\u003c\/li\u003e\n\u003cli\u003eLI trip functions: Provides Long-Time and Instantaneous overcurrent response.\u003c\/li\u003e\n\u003cli\u003e10 kA interrupting rating: Meets standard short-circuit protection requirements.\u003c\/li\u003e\n\u003cli\u003eSupports large conductor sizes: Accepts 2 AWG to 300 kcmil copper or aluminum wire.\u003c\/li\u003e\n\u003cli\u003eLine-side terminals included: Ensures secure termination and efficient power delivery.\u003c\/li\u003e\n\u003cli\u003eCompatible with multiple Eaton breaker types: Can series-combine with BD, BR, BQ, BQC, and GFCB breakers for higher system interrupt ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BW2175 delivers the reliability and precision required for HVAC equipment, service entrance modules, and general overcurrent protection applications.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47431237730602,"sku":"BW2175","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/BW2175.webp?v=1706280398","url":"https:\/\/iqelectro.com\/products\/eaton-bw2175-main-circuit-breaker-secure-packaging","provider":"IQElectro","version":"1.0","type":"link"}