{"product_id":"eaton-ch120af-magnetic-circuit-breaker-reliable-delivery","title":"CH120AF | Eaton CH Series 1-Pole 20A 120V AFCI Thermal Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Eaton CH120AF is a molded case circuit breaker designed for single-phase residential applications requiring advanced arc fault protection. Rated for 120-volt operation with a 20-amp capacity, it provides dependable overcurrent response while addressing arc fault hazards.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9458%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eCH120AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eLoad Center Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eCH Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eAdditional Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eAFCI (Arc Fault Circuit Interrupter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eLI – Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003e10 kA @ 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.965%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8881%; height: 19.6px;\"\u003eResidential branch-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About CH120AF\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe CH120AF is part of Eaton’s CH Series, engineered to enhance residential electrical safety through the integration of arc fault detection and traditional overcurrent protection. Designed for 120-volt single-phase systems, this breaker supports a 20-amp load and installs easily in compatible CH load centers using a plug-in mounting design. Its AFCI functionality identifies potentially dangerous arc faults, helping to prevent electrical fires, while the thermal magnetic LI trip mechanism provides dependable overload and short-circuit response. With a 10 kA interrupt rating, the CH120AF delivers solid protection against fault currents in modern home electrical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAFCI protection: Detects hazardous arc faults to reduce electrical fire risk.\u003c\/li\u003e\n\u003cli\u003eSingle-pole configuration: Designed for standard residential branch circuits.\u003c\/li\u003e\n\u003cli\u003e20-amp rating: Provides reliable protection for common 120-volt applications.\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip: Ensures accurate overload and instantaneous fault response.\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating: Supports standard residential fault-clearing requirements.\u003c\/li\u003e\n\u003cli\u003ePlug-in connection: Allows quick and secure installation in CH Series load centers.\u003c\/li\u003e\n\u003cli\u003eLI trip functions: Provides long-time overload and instantaneous short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eDurable molded case design: Built for long-term use in home electrical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CH120AF delivers the reliability and precision required for safeguarding residential electrical circuits while offering advanced arc fault protection.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48554205348138,"sku":"CH120AF","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/CH120AF.jpg?v=1716814002","url":"https:\/\/iqelectro.com\/products\/eaton-ch120af-magnetic-circuit-breaker-reliable-delivery","provider":"IQElectro","version":"1.0","type":"link"}