{"product_id":"eaton-ch2125-thermal-magnetic-circuit-breaker-ready-to-ship","title":"CH2125 | Eaton CH Series 125A 120\/240V 2-Pole Thermal Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Eaton CH2125 is a molded case circuit breaker designed to provide thermal-magnetic protection for single-phase electrical distribution systems. Rated at 125 amps and 120\/240 volts, it offers dependable overload and short-circuit interruption for residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eCH2125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eLoad Center Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eCH Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003e120\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eLI – Long-Time \u0026amp; Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003e10kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eThermal-Magnetic Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6875%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1746%;\"\u003eResidential \u0026amp; Commercial Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About CH2125\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe CH2125 is a two-pole breaker from Eaton’s CH Series engineered for reliable overcurrent protection in 120\/240-volt single-phase systems. Built with a thermal-magnetic trip unit, it provides long-time overload sensing and instantaneous fault clearing to protect wiring and downstream equipment. Its plug-in configuration allows fast, secure installation in CH load centers, supporting both new construction and replacement applications. With a 125A rating, 10kA interrupting capacity at 240V, and a 40°C operating design, the breaker delivers dependable performance for a broad range of residential and commercial electrical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e125-Amp Load Capacity: Supports higher-demand branch circuits and subfeed applications commonly found in residential and commercial environments.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip Mechanism: Provides dual protection by sensing both long-duration overloads and instantaneous short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003eLong-Time \u0026amp; Instantaneous Functions: Ensures selective, accurate response to varying fault levels, enhancing overall system safety.\u003c\/li\u003e\n\u003cli\u003eTwo-Pole Configuration: Enables simultaneous protection of both legs of a 120\/240-volt single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e10kA Interrupting Capacity: Safely clears fault currents up to 10,000 amps at 240 volts, reducing risks of equipment damage.\u003c\/li\u003e\n\u003cli\u003ePlug-In Installation: Allows quick, secure mounting in Eaton CH load centers without additional hardware.\u003c\/li\u003e\n\u003cli\u003e40°C Rated Design: Supports stable breaker performance under standard operating temperature conditions.\u003c\/li\u003e\n\u003cli\u003eDurable CH Series Construction: Known for robust mechanical strength and long-term reliability in demanding distribution setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CH2125 delivers the reliability and precision required for protecting 120\/240-volt single-phase electrical systems in residential and commercial applications.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48414843404586,"sku":"CH2125","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/CH2125.jpg?v=1715607169","url":"https:\/\/iqelectro.com\/products\/eaton-ch2125-thermal-magnetic-circuit-breaker-ready-to-ship","provider":"IQElectro","version":"1.0","type":"link"}