{"product_id":"eaton-cvs2125xmm-125a-2-pole-circuit-breaker-trusted-supplier","title":"CVS2125XMM | Eaton 125A 2-Pole Bolt-On Molded Case Circuit Breaker for 240V Applications","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Eaton CVS2125XMM is a two-pole, 125A molded case circuit breaker designed to provide dependable thermal-magnetic protection for 240V electrical systems. This breaker offers long-time and instantaneous trip functions suited for demanding branch-circuit and main-breaker applications. Its bolt-on configuration and durable CVS-series construction support stable installation in commercial, industrial, and energy-generation environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCVS2125XMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kAIC @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time \u0026amp; Instantaneous (Thermal Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries \/ Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCVS Series \/ CVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRenewable energy, conventional generation, marine systems, data centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#6 – 4\/0 Al\/Cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDominican Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0\" × 3.5\" × 7.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.75 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eCVS2125XMM\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe CVS2125XMM is part of Eaton’s CVS Series, a line of molded case breakers built for secure bolt-on mounting and high interrupting performance. It incorporates a thermal-magnetic trip system that supports long-time overload response and instantaneous short-circuit protection. This breaker is compatible with a variety of panel and distribution systems, including applications in renewable energy, marine equipment, and data-center infrastructure. Supplied with a mounting hardware kit, it is suitable for use as a main breaker in installations requiring 125A protection at 240V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e125A Protection Capacity: Provides reliable current handling for higher-load circuits and main-breaker applications.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip: Ensures long-time overload and instantaneous short-circuit protection in one unit.\u003c\/li\u003e\n\u003cli\u003eBolt-On Connection: Offers secure attachment to compatible panelboards for stable electrical performance.\u003c\/li\u003e\n\u003cli\u003e25 kA Interrupt Rating: Supports safe fault-clearing capability at 240V for commercial installations.\u003c\/li\u003e\n\u003cli\u003eCVS Series Construction: Built within Eaton’s robust CVS platform for consistent performance in demanding environments.\u003c\/li\u003e\n\u003cli\u003eTwo-Pole Configuration: Supports 240V circuits requiring dual-pole protection.\u003c\/li\u003e\n\u003cli\u003eIncludes Mounting Hardware: Supplied with installation hardware for straightforward panel integration.\u003c\/li\u003e\n\u003cli\u003eCSA and UL Rated: Certified to UL 489 and CSA C22.2 standards for broad compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CVS2125XMM delivers the reliability and precision required for molded case protection in commercial and industrial power systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50852002431274,"sku":"CVS2125XMM","price":574.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/CVS2125XMM-1_b8ffaec1-ceb8-417c-a62e-c932245a948d.jpg?v=1763562869","url":"https:\/\/iqelectro.com\/products\/eaton-cvs2125xmm-125a-2-pole-circuit-breaker-trusted-supplier","provider":"IQElectro","version":"1.0","type":"link"}