{"product_id":"eaton-esr5-no-41-24vac-dc-single-channel-safety-relay-24vac-dc-with-4-no-and-1-nc-contacts","title":"Eaton ESR5-NO-41-24VAC-DC Single-Channel Safety Relay 24VAC\/DC with 4 NO and 1 NC Contacts","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Eaton ESR5-NO-41-24VAC-DC is a single-channel safety relay designed to monitor emergency stop circuits, protective door switches, and safety-related control functions in industrial machinery. Eaton part number ESR5-NO-41-24VAC-DC operates on 24 VAC\/DC and provides four normally open safety contacts and one normally closed signaling contact for controlled shutdown and status monitoring.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNew\/Never \u003c\/span\u003e\u003cspan\u003eUsed \u003c\/span\u003e\u003cspan\u003eSurplus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eEaton \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003eCutler-Hammer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial \u003c\/span\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003e\u0026amp; \u003c\/span\u003e\u003cspan\u003eAutomation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eESR5-NO-41-24VAC-DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eRelays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eESR5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSingle-Channel \u003c\/span\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Control Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eVAC\/DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAC Frequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e50\/60 \u003c\/span\u003e\u003cspan\u003eHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Input Channels\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4 \u003c\/span\u003e\u003cspan\u003eNormally \u003c\/span\u003e\u003cspan\u003eOpen \u003c\/span\u003e\u003cspan\u003e(NO)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSignaling Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eNormally \u003c\/span\u003e\u003cspan\u003eClosed \u003c\/span\u003e\u003cspan\u003e(NC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4 \u003c\/span\u003e\u003cspan\u003eNO \u003c\/span\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003e+ \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eNC \u003c\/span\u003e\u003cspan\u003eAuxiliary\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4 \u003c\/span\u003e\u003cspan\u003eA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSilver \u003c\/span\u003e\u003cspan\u003eTin \u003c\/span\u003e\u003cspan\u003eOxide, \u003c\/span\u003e\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003ePlated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStart Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eManual \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFeedback Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSupported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStop Category\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCategory \u003c\/span\u003e\u003cspan\u003e0, \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003e60204\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eUp \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ePL \u003c\/span\u003e\u003cspan\u003ec, \u003c\/span\u003e\u003cspan\u003eEN \u003c\/span\u003e\u003cspan\u003eISO \u003c\/span\u003e\u003cspan\u003e13849-1, \u003c\/span\u003e\u003cspan\u003eSubject \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eFault \u003c\/span\u003e\u003cspan\u003eExclusions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSIL \u003c\/span\u003e\u003cspan\u003e1, \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003e62061\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePFHd\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4.05 \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e10⁻¹⁰ \u003c\/span\u003e\u003cspan\u003eper \u003c\/span\u003e\u003cspan\u003eHour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eB10d Value\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e230,000 \u003c\/span\u003e\u003cspan\u003eSwitching \u003c\/span\u003e\u003cspan\u003eCycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Lifespan\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e10,000,000 \u003c\/span\u003e\u003cspan\u003eOperations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRecovery Time\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1000 \u003c\/span\u003e\u003cspan\u003ems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Switching Frequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.5 \u003c\/span\u003e\u003cspan\u003eHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e65 \u003c\/span\u003e\u003cspan\u003emA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e140 \u003c\/span\u003e\u003cspan\u003emA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e5.16 \u003c\/span\u003e\u003cspan\u003eW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eRated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4000 \u003c\/span\u003e\u003cspan\u003eV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIII\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e-4°F \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e131°F \u003c\/span\u003e\u003cspan\u003e(-20°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e55°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e35 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003eDIN \u003c\/span\u003e\u003cspan\u003eRail\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eM3 \u003c\/span\u003e\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eTerminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePolyamide \u003c\/span\u003e\u003cspan\u003e(PA), \u003c\/span\u003e\u003cspan\u003eNon-Reinforced\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e99 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003eH \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e22.5 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003eW \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e114.5 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003eD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eUL, \u003c\/span\u003e\u003cspan\u003eCSA, \u003c\/span\u003e\u003cspan\u003eCE, \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003e62061, \u003c\/span\u003e\u003cspan\u003eEN \u003c\/span\u003e\u003cspan\u003eISO \u003c\/span\u003e\u003cspan\u003e13849-1, \u003c\/span\u003e\u003cspan\u003eEN \u003c\/span\u003e\u003cspan\u003e50178\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4015081168415\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.48 \u003c\/span\u003e\u003cspan\u003elb\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eESR5-NO-41-24VAC-DC\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eESR5-NO-41-24VAC-DC \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003epart \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eEaton's \u003c\/span\u003e\u003cspan\u003eESR5 \u003c\/span\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eelectronic \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003erelays \u003c\/span\u003e\u003cspan\u003edeveloped \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003emachine \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003eautomation \u003c\/span\u003e\u003cspan\u003eapplications. \u003c\/span\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cspan\u003e22.5 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003epolyamide \u003c\/span\u003e\u003cspan\u003eenclosure \u003c\/span\u003e\u003cspan\u003efeatures \u003c\/span\u003e\u003cspan\u003escrew \u003c\/span\u003e\u003cspan\u003eterminals, \u003c\/span\u003e\u003cspan\u003e35 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003eDIN-rail \u003c\/span\u003e\u003cspan\u003emounting, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003epositively \u003c\/span\u003e\u003cspan\u003eguided \u003c\/span\u003e\u003cspan\u003erelay \u003c\/span\u003e\u003cspan\u003econtacts \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003esafety-related \u003c\/span\u003e\u003cspan\u003eswitching. \u003c\/span\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003emodule \u003c\/span\u003e\u003cspan\u003esupports \u003c\/span\u003e\u003cspan\u003emanual \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eautomatic \u003c\/span\u003e\u003cspan\u003estart \u003c\/span\u003e\u003cspan\u003efunctions, \u003c\/span\u003e\u003cspan\u003efeedback \u003c\/span\u003e\u003cspan\u003ecircuit \u003c\/span\u003e\u003cspan\u003emonitoring, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003esingle-channel \u003c\/span\u003e\u003cspan\u003eevaluation \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eemergency \u003c\/span\u003e\u003cspan\u003estop \u003c\/span\u003e\u003cspan\u003ebuttons \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprotective \u003c\/span\u003e\u003cspan\u003edoor \u003c\/span\u003e\u003cspan\u003eswitches. \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eCategory \u003c\/span\u003e\u003cspan\u003e0 \u003c\/span\u003e\u003cspan\u003eemergency \u003c\/span\u003e\u003cspan\u003estopping \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003e60204, \u003c\/span\u003e\u003cspan\u003eit \u003c\/span\u003e\u003cspan\u003esupports \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003eapplications \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eSIL \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ePerformance \u003c\/span\u003e\u003cspan\u003eLevel \u003c\/span\u003e\u003cspan\u003ec \u003c\/span\u003e\u003cspan\u003eunder \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003especified \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003econditions \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003efault \u003c\/span\u003e\u003cspan\u003eexclusions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSingle-Channel \u003c\/span\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eMonitoring: \u003c\/span\u003e\u003cspan\u003eEvaluates \u003c\/span\u003e\u003cspan\u003eone \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003einput \u003c\/span\u003e\u003cspan\u003echannel \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eemergency \u003c\/span\u003e\u003cspan\u003estop \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprotective \u003c\/span\u003e\u003cspan\u003edoor \u003c\/span\u003e\u003cspan\u003eapplications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eFour \u003c\/span\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eOutputs: \u003c\/span\u003e\u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003efour \u003c\/span\u003e\u003cspan\u003enormally \u003c\/span\u003e\u003cspan\u003eopen, \u003c\/span\u003e\u003cspan\u003enon-delayed \u003c\/span\u003e\u003cspan\u003eenabling \u003c\/span\u003e\u003cspan\u003ecurrent \u003c\/span\u003e\u003cspan\u003epaths \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003esafety-related \u003c\/span\u003e\u003cspan\u003eswitching.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary \u003c\/span\u003e\u003cspan\u003eSignaling \u003c\/span\u003e\u003cspan\u003eContact: \u003c\/span\u003e\u003cspan\u003eIncludes \u003c\/span\u003e\u003cspan\u003eone \u003c\/span\u003e\u003cspan\u003enormally \u003c\/span\u003e\u003cspan\u003eclosed \u003c\/span\u003e\u003cspan\u003econtact \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003estatus \u003c\/span\u003e\u003cspan\u003eindication \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003emonitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eVAC\/DC \u003c\/span\u003e\u003cspan\u003eSupply: \u003c\/span\u003e\u003cspan\u003eOperates \u003c\/span\u003e\u003cspan\u003efrom \u003c\/span\u003e\u003cspan\u003eeither \u003c\/span\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eVAC \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eVDC \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003epower.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eManual \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eAutomatic \u003c\/span\u003e\u003cspan\u003eStart: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003econfigurable \u003c\/span\u003e\u003cspan\u003erestart \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003ecircuit \u003c\/span\u003e\u003cspan\u003edesign.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eFeedback \u003c\/span\u003e\u003cspan\u003eCircuit \u003c\/span\u003e\u003cspan\u003eMonitoring: \u003c\/span\u003e\u003cspan\u003eAllows \u003c\/span\u003e\u003cspan\u003emonitoring \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eexternal \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003edevices \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003ededicated \u003c\/span\u003e\u003cspan\u003efeedback \u003c\/span\u003e\u003cspan\u003ecircuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePositive-Guided \u003c\/span\u003e\u003cspan\u003eContacts: \u003c\/span\u003e\u003cspan\u003eUses \u003c\/span\u003e\u003cspan\u003emechanically \u003c\/span\u003e\u003cspan\u003elinked \u003c\/span\u003e\u003cspan\u003econtact \u003c\/span\u003e\u003cspan\u003etechnology \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003esafety-related \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003eapplications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eReinforced \u003c\/span\u003e\u003cspan\u003eInsulation: \u003c\/span\u003e\u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003ereinforced \u003c\/span\u003e\u003cspan\u003einsulation \u003c\/span\u003e\u003cspan\u003ebetween \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003einput \u003c\/span\u003e\u003cspan\u003ecircuit, \u003c\/span\u003e\u003cspan\u003enormally \u003c\/span\u003e\u003cspan\u003eclosed \u003c\/span\u003e\u003cspan\u003econtact, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eenabling \u003c\/span\u003e\u003cspan\u003ecurrent \u003c\/span\u003e\u003cspan\u003epaths.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCategory \u003c\/span\u003e\u003cspan\u003e0 \u003c\/span\u003e\u003cspan\u003eEmergency \u003c\/span\u003e\u003cspan\u003eStop: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eimmediate \u003c\/span\u003e\u003cspan\u003eremoval \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003epower \u003c\/span\u003e\u003cspan\u003efrom \u003c\/span\u003e\u003cspan\u003emachine \u003c\/span\u003e\u003cspan\u003eactuators \u003c\/span\u003e\u003cspan\u003eaccording \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003e60204.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSafety \u003c\/span\u003e\u003cspan\u003eCertification: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eapplications \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eSIL \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eunder \u003c\/span\u003e\u003cspan\u003eIEC \u003c\/span\u003e\u003cspan\u003e62061 \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ePL \u003c\/span\u003e\u003cspan\u003ec \u003c\/span\u003e\u003cspan\u003eunder \u003c\/span\u003e\u003cspan\u003eEN \u003c\/span\u003e\u003cspan\u003eISO \u003c\/span\u003e\u003cspan\u003e13849-1, \u003c\/span\u003e\u003cspan\u003esubject \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003especified \u003c\/span\u003e\u003cspan\u003econditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCompact \u003c\/span\u003e\u003cspan\u003eDIN-Rail \u003c\/span\u003e\u003cspan\u003eHousing: \u003c\/span\u003e\u003cspan\u003eFeatures \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003e22.5 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003ewide \u003c\/span\u003e\u003cspan\u003eenclosure \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003einstallation \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003estandard \u003c\/span\u003e\u003cspan\u003e35 \u003c\/span\u003e\u003cspan\u003emm \u003c\/span\u003e\u003cspan\u003emounting \u003c\/span\u003e\u003cspan\u003erails.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic \u003c\/span\u003e\u003cspan\u003eLED: \u003c\/span\u003e\u003cspan\u003eIntegrated \u003c\/span\u003e\u003cspan\u003egreen \u003c\/span\u003e\u003cspan\u003eLED \u003c\/span\u003e\u003cspan\u003eprovides \u003c\/span\u003e\u003cspan\u003estatus \u003c\/span\u003e\u003cspan\u003eindication \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003erelay's \u003c\/span\u003e\u003cspan\u003eoperating \u003c\/span\u003e\u003cspan\u003enetwork.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eESR5-NO-41-24VAC-DC \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ereliability \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprecision \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003eemergency \u003c\/span\u003e\u003cspan\u003estop \u003c\/span\u003e\u003cspan\u003emonitoring, \u003c\/span\u003e\u003cspan\u003eprotective \u003c\/span\u003e\u003cspan\u003edoor \u003c\/span\u003e\u003cspan\u003esupervision, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003esafety-related \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003emachinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":52940512002346,"sku":"ESR5-NO-41-24VAC-DC","price":359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/ESR5-NO-21-24VAC-DC_R.jpg?v=1792003010","url":"https:\/\/iqelectro.com\/products\/eaton-esr5-no-41-24vac-dc-single-channel-safety-relay-24vac-dc-with-4-no-and-1-nc-contacts","provider":"IQElectro","version":"1.0","type":"link"}