{"product_id":"eaton-ghqrd2030-remote-circuit-breaker-available-now","title":"GHQRD2030 | Eaton GHQR 30A 2-Pole Remote Operated Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"495\" data-start=\"140\"\u003eThe Eaton GHQRD2030 is a two-pole, remote-operated molded case circuit breaker designed for controlled switching and overcurrent protection in commercial and industrial electrical systems. Rated at 30A, this Eaton GHQRD2030 operates within 480VAC systems and uses a 24 VDC solenoid to enable remote actuation while maintaining thermal magnetic protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9744%; height: 392.014px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eGHQRD2030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eGHQR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eRemote Operated Molded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eSystem Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003e14 kAIC at 277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003e24 VDC Solenoid Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eLine Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003eUL 489, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 31.1749%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.1827%; height: 19.6007px;\"\u003e5.19 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003eGHQRD2030\u003c\/h4\u003e\n\u003cp data-start=\"528\" data-end=\"1138\"\u003eThe GHQRD2030 is part of Eaton’s GHQR series, engineered to combine standard molded case protection with remote operating capability. It incorporates a thermal magnetic trip unit that provides long-time and instantaneous protection against overloads and short-circuit conditions. The breaker is configured with bolt-on mounting and line-side lug terminals, supporting secure installation in panelboards and distribution equipment. Designed for systems requiring centralized or automated control, it supports rectified or half-rectified AC control power for the solenoid operator and meets UL and CSA standards.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Operated Design: Integrated 24 VDC solenoid enables electrical remote switching and control.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Protection: Provides long-time and instantaneous trip response for circuit safety.\u003c\/li\u003e\n\u003cli\u003e30 Amp Current Rating: Suitable for moderate-load branch and control circuits.\u003c\/li\u003e\n\u003cli\u003eTwo-Pole Configuration: Supports single-phase applications requiring dual-conductor protection.\u003c\/li\u003e\n\u003cli\u003e14 kA Interrupting Capacity: Rated at 14kAIC at 277V for effective fault interruption.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting Style: Ensures secure mechanical and electrical installation.\u003c\/li\u003e\n\u003cli\u003eGHQR Series Construction: Designed for reliability in controlled power distribution environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe GHQRD2030 delivers the reliability and precision required for remotely operated circuit protection and controlled power distribution systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":51041647657258,"sku":"GHQRD2030","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/GHQRD2030_C.jpg?v=1768046151","url":"https:\/\/iqelectro.com\/products\/eaton-ghqrd2030-remote-circuit-breaker-available-now","provider":"IQElectro","version":"1.0","type":"link"}