{"product_id":"eaton-jgh3250fag-molded-case-breaker-responsive-support","title":"JGH3250FAG | Eaton Series G 250A 3-Pole Molded Case Circuit Breaker 600VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"18\" data-end=\"473\"\u003eThe Eaton JGH3250FAG is a molded case circuit breaker designed to provide reliable overcurrent protection in commercial and industrial power distribution systems. This Eaton part number JGH3250FAG features a 250 amp rating and supports up to 600 Vac operation for three-phase electrical circuits. Built within the Series G JG frame platform, it delivers dependable thermal-magnetic protection for panelboards, switchboards, and motor control applications.\u003c\/p\u003e\n\u003ch3 data-start=\"475\" data-end=\"498\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJGH3250FAG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJG Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT185 Thermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kAIC @ 240 Vac; 65 kAIC @ 480 Vac; 25 kAIC @ 600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine and Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE Marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified, IEC Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L×W×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.57 × 4.13 × 4.13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About JGH3250FAG\u003c\/h4\u003e\n\u003cp data-start=\"499\" data-end=\"1118\"\u003eThe JGH3250FAG is a complete molded case circuit breaker from Eaton’s Series G product family, engineered for robust circuit protection in demanding electrical installations. It utilizes a fixed thermal and adjustable magnetic trip system to provide reliable overload and short-circuit protection. The breaker is built on the JG frame and supports three-pole configurations for three-phase power systems commonly found in industrial and commercial facilities. Designed with line-and-load terminals and metric mounting hardware, the device ensures compatibility with modern electrical panels and distribution assemblies.\u003c\/p\u003e\n\u003ch3 data-start=\"1120\" data-end=\"1138\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e250 Amp Current Rating: Provides reliable overcurrent protection for circuits operating up to 250 A.\u003c\/li\u003e\n\u003cli\u003eSeries G JG Frame Design: Engineered for Eaton’s Series G platform to ensure durability and consistent performance.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip Protection: Combines thermal overload protection with magnetic short-circuit response.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated up to 100 kAIC at 240 Vac and 65 kAIC at 480 Vac for demanding fault conditions.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Suitable for protecting three-phase electrical distribution systems.\u003c\/li\u003e\n\u003cli\u003e600 Vac Voltage Rating: Supports industrial and commercial systems operating up to 600 Vac.\u003c\/li\u003e\n\u003cli\u003eLine and Load Terminals: Simplifies installation within switchboards, panelboards, and distribution equipment.\u003c\/li\u003e\n\u003cli\u003eUL, CSA, and IEC Certifications: Complies with multiple international electrical safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe JGH3250FAG delivers the reliability and precision required for protecting industrial power distribution circuits and commercial electrical infrastructure.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":51219987464490,"sku":"JGH3250FAG","price":3899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/JGH305032G_C.jpg?v=1772920481","url":"https:\/\/iqelectro.com\/products\/eaton-jgh3250fag-molded-case-breaker-responsive-support","provider":"IQElectro","version":"1.0","type":"link"}