{"product_id":"eaton-pdd23g0225tffl-molded-case-circuit-breaker-ships-fast","title":"Eaton PDD23G0225TFFL Power Defense 225A 3-Pole Molded Case Circuit Breaker 240V","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"461\"\u003eThe Eaton PDD23G0225TFFL is a Power Defense molded case circuit breaker designed to provide reliable overcurrent protection for low-voltage electrical distribution systems. Eaton part number PDD23G0225TFFL features a 225 A rating and a three-pole configuration with an advanced electronic trip unit for accurate fault detection. Its compact Frame 2 design and high interrupting capacity make it suitable for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePDD23G0225TFFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded case circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Defense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePD2 UL\/CSA Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Breaker Frame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT298 electronic trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard terminals load only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kAIC at 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Interrupt Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kAIC at 250 Vdc; 10 kAIC at 125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489; CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Dimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88.9 × 104.6 × 152.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Selling Policy 25-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PDD23G0225TFFL\u003c\/h4\u003e\n\u003cp data-start=\"463\" data-end=\"1065\"\u003eThe PDD23G0225TFFL is a complete molded case circuit breaker from Eaton’s Power Defense PD2 series, engineered for UL and CSA applications. Built on a Frame 2 platform, it incorporates a T298 electronic trip unit that provides precise protection against overload and short-circuit conditions. The breaker is equipped with standard load-side terminals and is rated for 240 Vac systems, making it ideal for panelboards and switchgear installations. Designed to meet UL 489 and CSA standards with RoHS compliance, it delivers dependable performance in modern electrical infrastructure.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e225 Amp Current Rating: Provides reliable protection for feeder and branch circuits in commercial and industrial systems.\u003c\/li\u003e\n\u003cli\u003ePower Defense PD2 Platform: Advanced Eaton circuit breaker technology for enhanced system protection and reliability.\u003c\/li\u003e\n\u003cli\u003eT298 Electronic Trip Unit: Ensures accurate detection and response to overload and short-circuit faults.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupt Capacity: Rated up to 65 kAIC at 240 Vac for safe interruption of high fault currents.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Designed for use in three-phase electrical distribution systems.\u003c\/li\u003e\n\u003cli\u003eCompact Frame 2 Design: Space-efficient construction for integration into panelboards and switchgear.\u003c\/li\u003e\n\u003cli\u003eLoad-Side Terminal Configuration: Simplifies installation with secure conductor connections.\u003c\/li\u003e\n\u003cli\u003eUL and CSA Certified: Meets key North American safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PDD23G0225TFFL delivers the reliability and precision required for protecting low-voltage electrical distribution circuits in commercial and industrial environments.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":51261185720618,"sku":"PDD23G0225TFFL","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/PDG23G0225TFFN_C_c11b36db-c952-45a0-b9c6-02cec36cf33d.jpg?v=1773777403","url":"https:\/\/iqelectro.com\/products\/eaton-pdd23g0225tffl-molded-case-circuit-breaker-ships-fast","provider":"IQElectro","version":"1.0","type":"link"}