{"product_id":"eaton-pdg23m0030tffj-power-defense-30a-molded-case-circuit-breaker-600vac-3-pole","title":"Eaton PDG23M0030TFFJ Power Defense 30A Molded Case Circuit Breaker 600VAC 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"401\"\u003eThe Eaton PDG23M0030TFFJ is a Power Defense molded case circuit breaker designed to provide precise overcurrent protection in low-voltage power distribution systems. Eaton PDG23M0030TFFJ features a 30 A rating with advanced trip functionality for reliable fault interruption. It is suited for commercial and industrial applications requiring compact, high-performance circuit protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9755%; height: 392.014px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003ePDG23M0030TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eMolded case circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003ePower Defense (PD2 Global)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eFrame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eT298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eThree-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e65 kAIC at 480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupt Rating (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e35 kAIC at 600 Vac; 100 kAIC at 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eDC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e22 kAIC at 250 Vdc; 22 kAIC at 125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eStandard line and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eUL 489, IEC 60947-2, CSA, CCC Marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eProduct Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e8 in (L) x 6 in (H) x 6 in (W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 34.4251%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.0421%; height: 19.6007px;\"\u003e5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PDG23M0030TFFJ\u003c\/h4\u003e\n\u003cp data-start=\"403\" data-end=\"950\"\u003eThe PDG23M0030TFFJ is a PD2 Global series molded case circuit breaker from Eaton, engineered for dependable protection and control of electrical circuits. It incorporates a T298 trip unit, offering accurate response to overload and short-circuit conditions. Designed for operation at up to 600 Vac, it supports a wide range of global applications and complies with UL, IEC, CSA, and CCC standards. With a compact Frame 2 design and standard line and load terminals, it integrates easily into panelboards and switchgear systems.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 Amp Rating: Provides reliable protection for low-current distribution circuits.\u003c\/li\u003e\n\u003cli\u003eT298 Trip Unit: Ensures accurate and consistent response to overload and fault conditions.\u003c\/li\u003e\n\u003cli\u003ePD2 Global Platform: Designed for worldwide applications with multi-standard compliance.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated up to 65 kAIC at 480 Vac for robust fault protection.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Suitable for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003eStandard Line and Load Terminals: Simplifies installation and wiring connections.\u003c\/li\u003e\n\u003cli\u003eWide Voltage Compatibility: Supports up to 600 Vac and various DC ratings.\u003c\/li\u003e\n\u003cli\u003eCertified Compliance: Meets UL 489, IEC 60947-2, CSA, and CCC standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PDG23M0030TFFJ delivers the reliability and precision required for protecting electrical circuits in commercial and industrial power distribution systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":51278398062890,"sku":"PDG23M0030TFFJ","price":679.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/PDG23P0225TFFN_C_aad6a324-1a98-4478-aef9-377fd0ba090f.jpg?v=1774030899","url":"https:\/\/iqelectro.com\/products\/eaton-pdg23m0030tffj-power-defense-30a-molded-case-circuit-breaker-600vac-3-pole","provider":"IQElectro","version":"1.0","type":"link"}