{"product_id":"eaton-qc2050-thermal-magnetic-breaker-ships-overnight","title":"QC2050 | Eaton Quicklag Type QC 2-Pole Thermal-Magnetic Circuit Breaker 50 A 120\/240 Vac","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"361\" data-start=\"111\"\u003eThe Eaton QC2050 is a 2-pole industrial circuit breaker rated at 50 A for 120\/240 Vac electrical systems. It uses thermal-magnetic trip technology to provide reliable overload and short-circuit protection in industrial applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%; height: 352.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eQC2050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eThermal-Magnetic Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries \/ Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eQuicklag Type QC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eIndustrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e120\/240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e10 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eInterchangeability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003eNon-interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e4.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e2.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4585%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.4041%; height: 19.6px;\"\u003e0.75 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About QC2050\u003c\/h4\u003e\n\u003cp\u003eThe QC2050 is an industrial-grade circuit breaker from Eaton’s Quicklag Type QC product family, developed for dependable protection of low-voltage power circuits. Its thermal-magnetic trip mechanism provides coordinated response to prolonged overloads and instantaneous short-circuit conditions. The breaker is designed as a non-interchangeable unit, ensuring correct application within specified circuit configurations. Compact dimensions and rugged construction make it suitable for use in control panels and industrial distribution equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicklag Type QC design: Engineered specifically for industrial applications requiring consistent and predictable circuit protection.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip mechanism: Combines thermal overload sensing with magnetic instantaneous tripping for short-circuit events.\u003c\/li\u003e\n\u003cli\u003e50 A current rating: Supports medium-load branch circuits and equipment protection in industrial systems.\u003c\/li\u003e\n\u003cli\u003e2-pole configuration: Enables protection and switching of single-phase 120\/240 Vac circuits.\u003c\/li\u003e\n\u003cli\u003e10 kAIC interrupting capacity: Safely interrupts fault currents to protect downstream equipment and wiring.\u003c\/li\u003e\n\u003cli\u003eNon-interchangeable construction: Prevents improper replacement and ensures compatibility with designated applications.\u003c\/li\u003e\n\u003cli\u003eCompact form factor: Allows efficient use of space in industrial panels and enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe QC2050 delivers the reliability and precision required for secure overcurrent protection in industrial electrical systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48744614297898,"sku":"QC2050","price":49.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/qc2050-1.webp?v=1718796730","url":"https:\/\/iqelectro.com\/products\/eaton-qc2050-thermal-magnetic-breaker-ships-overnight","provider":"IQElectro","version":"1.0","type":"link"}