{"product_id":"edwards-a65501906-rv12-two-stage-rotary-vane-vacuum-pump-115-230v","title":"Edwards A65501906 RV12 Two-Stage Rotary Vane Vacuum Pump 115\/230V","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Edwards A65501906 is an RV12 two-stage rotary vane vacuum pump designed for industrial, laboratory, and scientific vacuum applications. It operates on 115\/230V single-phase power and delivers pumping speeds of 12.0 m³\/h at 50 Hz and 14.2 m³\/h at 60 Hz, supporting efficient gas and vapor removal.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 68.5815%; height: 554.222px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 46.9028px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eNew\/Never Used Surplus\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.7778px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eEdwards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 52.7778px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eIndustrial Vacuum Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36.7778px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eA65501906\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42.7778px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eRotary Vane Vacuum Pumps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5972px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePump Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eRV12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57.0278px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePump Technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eOil-Sealed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57.0278px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e0.74 HP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 46.0278px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e370 W (50 Hz) \/ 440 W (60 Hz)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5972px;\"\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e115\/230V (Factory Set to 115V)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eSingle Phase\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePumping Speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e12.0 m³\/h (50 Hz) \/ 14.2 m³\/h (60 Hz)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eUltimate Pressure (Without Gas Ballast)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e2 × 10⁻³ mbar\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eUltimate Pressure (With Gas Ballast)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e6 × 10⁻² mbar\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Water Vapor Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e290 g\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eGas Ballast\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eTwo-Position\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInlet Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eNW25 \/ KF25\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eAir Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Level\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e48 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOil Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e1 L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Oil\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003eEdwards Ultragrade Performance 19\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e19.29 × 6.22 × 9.02 in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.49%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.1954%;\"\u003e\n\u003cp\u003e58 lb \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About A65501906\u003c\/h4\u003e\n\u003cp\u003eThe A65501906 belongs to the Edwards RV series of oil-sealed rotary vane vacuum pumps, featuring a two-stage compression mechanism. Its universal motor supports 50\/60 Hz operation and is factory configured for 115V supply in the US market. The pump incorporates a two-position gas ballast, an inlet anti-suckback valve, and a mode selector for adapting operation to different vacuum requirements. Its NW25 inlet and exhaust connections allow integration into compatible vacuum installations, while the oil-lubricated mechanism supports continuous operation and routine maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eTwo-Stage Compression: Oil-sealed rotary vane mechanism provides two-stage vacuum generation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003ePumping Speed: Delivers 12.0 m³\/h at 50 Hz and 14.2 m³\/h at 60 Hz.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eMotor Configuration: Universal single-phase motor rated for 115\/230V operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFactory Voltage Setting: Configured for 115V operation for the US market.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGas Ballast Control: Two-position system supports water vapor pumping rates of 60 g\/h and up to 290 g\/h.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAnti-Suckback Protection: Fast-acting inlet valve helps prevent oil from flowing back into the vacuum system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eOperating Mode Selector: Allows selection between high-vacuum and high-throughput operating modes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eVacuum Connections: NW25 inlet and exhaust flanges support compatible vacuum system connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe A65501906 delivers the reliability and precision required for industrial vacuum generation, laboratory processes, and gas and vapor handling.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":53478157615402,"sku":"A65501906","price":6347.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_d8f63c53-ca51-455d-83e9-c0fc4e39aa13.webp?v=1793990171","url":"https:\/\/iqelectro.com\/products\/edwards-a65501906-rv12-two-stage-rotary-vane-vacuum-pump-115-230v","provider":"IQElectro","version":"1.0","type":"link"}