{"product_id":"edwards-d02604000-apg100-xlc-corrosion-resistant-active-pirani-vacuum-gauge","title":"Edwards D02604000 APG100-XLC Corrosion-Resistant Active Pirani Vacuum Gauge","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe Edwards D02604000 is an APG100-XLC active Pirani vacuum gauge designed for pressure monitoring from atmosphere down to 1 × 10⁻⁴ mbar. Its corrosion-resistant sensor configuration and NW25 connection support installation in compatible laboratory and industrial vacuum systems.\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"3\" height=\"356\" style=\"width: 84.3603%; height: 450.657px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eEdwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eVacuum Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eD02604000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eActive Pirani Vacuum Gauges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003ePirani thermal conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eAtmosphere to 1 × 10⁻⁴ mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eVacuum Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eNW25 \/ DN 25 ISO-KF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eSensor Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eCorrosion-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 39.1875px;\"\u003e\u003cstrong\u003eController Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 39.1875px;\"\u003eEdwards TIC and compatible active gauge controllers and displays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eTypical Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e±15% below 10 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e15–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Output Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e0–10 V DC; pressure scaling of 1 V per decade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eSetpoint Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eOpen-collector transistor, rated 30 V DC, 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e+5 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e−30 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Bakeout Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 39.1875px;\"\u003e150 °C with electronics removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.2516%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.5402%; height: 19.5938px;\"\u003e0.22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eD02604000\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe D02604000 is the NW25-flanged corrosion-resistant model in the Edwards APG100 series. Its compact assembly combines a replaceable sensor tube with removable electronics for component servicing. The gauge connects to Edwards TIC instrument controllers and other compatible active gauge controllers and displays. A pressure output scaled at one volt per decade supports integration with vacuum monitoring and control equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eExtended Measurement Range: Measures pressure from atmosphere down to 1 × 10⁻⁴ mbar.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorrosion-Resistant Design: Uses the APG100-XLC sensor configuration for improved corrosion resistance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eController Compatibility: Works with Edwards TIC instruments and compatible active gauge controllers and displays.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure Signal Output: Provides a logarithmic pressure signal scaled at one volt per decade.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplaceable Sensor Tube: Allows sensor replacement while retaining serviceable electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable Setpoint: Provides a configurable switching output for pressure-based control and interlocking.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStatus Indicator: Uses an LED to indicate normal operation and fault conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBakeout Capability: Permits sensor tube bakeout up to 150 °C with the electronics removed.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe D02604000 delivers the reliability and precision required for vacuum pressure monitoring and pressure-based process control in laboratory and industrial systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52970746216746,"sku":"D02604000","price":1319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/edwards-linear-pirani-gauge-nw25-d02604000-674400_2048x2048_64ae6eae-17b2-4e45-b44b-baa4c46ea8db.jpg?v=1792180253","url":"https:\/\/iqelectro.com\/products\/edwards-d02604000-apg100-xlc-corrosion-resistant-active-pirani-vacuum-gauge","provider":"IQElectro","version":"1.0","type":"link"}