{"product_id":"edwards-d37232000-im-rs-232-serial-communications-module-for-dry-vacuum-pump-systems","title":"Edwards D37232000 iM RS-232 Serial Communications Module for Dry Vacuum Pump Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Edwards D37232000 is an iM Serial Communications Module designed to provide computer or process-tool communication with compatible Edwards semiconductor dry vacuum pumping systems. It uses RS-232 serial communication to enable remote monitoring, status retrieval, parameter access, and pump control for Edwards iQDP, iH, and iL systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVacuum Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD37232000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD372-32-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eiM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards iQDP, iH, and iL Dry Pumping Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEIA RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9600 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 data bits, 1 stop bit, no parity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-way D-type socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-way XLR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25% to 95% relative humidity at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4500 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePump System, Wall, or Structural Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan\u003eD37232000\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe D37232000 is an Edwards iM series Serial Communications Module, officially identified by the manufacturer as D372-32-000. The enclosed module incorporates an internal serial interface card and connects to a compatible dry pumping system through a four-way XLR connection while providing a nine-way D-type serial connection for external control equipment. It is compatible with Edwards iQDP, iH, and iL semiconductor dry pumping systems and can communicate with a computer, programmable controller, or suitable Supervisory Control and Data Acquisition software. The serial interface uses the EIA RS-232 protocol at 9600 baud with eight data bits, one stop bit, and no parity for structured pump control and monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eRS-232 Serial Communication: Provides an EIA RS-232 interface for communication between compatible Edwards dry pumping systems and external control equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDry Pump Compatibility: Designed for use with Edwards iQDP, iH, and iL semiconductor vacuum pumping systems. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eComputer-Based Monitoring: Allows a connected computer to retrieve operating status and pump parameters through suitable control or Supervisory Control and Data Acquisition software. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote Pump Control: Supports software-derived control commands without requiring direct electrical wiring to individual pump sensors, valves, or other monitored components. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDefined Serial Configuration: Communicates at 9600 baud using eight data bits, one stop bit, and no parity. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNine-Way Serial Connector: Provides a nine-way D-type socket for connection to compatible computer or process control equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFour-Way Pump Connection: Connects to the compatible Edwards pumping system through a four-way XLR interface. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting: Can be attached directly to a compatible iH or iL pumping system or installed separately on a wall or structural frame. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe D37232000 delivers the reliability and precision required for remote communication, operational monitoring, and control of compatible Edwards semiconductor dry vacuum pumping systems.\u003c\/p\u003e","brand":"Edwards EST","offers":[{"title":"Default Title","offer_id":52604939206954,"sku":"D37232000","price":2449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1200_bc4f4859-9f44-4ada-92ab-3b9f9874cc09.jpg?v=1789419499","url":"https:\/\/iqelectro.com\/products\/edwards-d37232000-im-rs-232-serial-communications-module-for-dry-vacuum-pump-systems","provider":"IQElectro","version":"1.0","type":"link"}