{"product_id":"edwards-est-3x-fib8-est3x-8-node-fiber-optic-fire-alarm-network-option-card","title":"Edwards EST 3X-FIB8 EST3X 8-Node Fiber Optic Fire Alarm Network Option Card","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Edwards EST 3X-FIB8 is a fiber-optic network option module designed to interconnect up to eight EST3X fire alarm control panels over a supervised fiber network. Edwards EST part number 3X-FIB8 supports single-mode and multimode fiber transceivers, Class A, Class B, and supported Class X network configurations, providing electrically isolated communications for distributed life-safety systems.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards EST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3X-FIB8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Optic Network Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEST3X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Optic Network Option Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Network Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 EST3X Nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3X-SFS \/ EST3X Fire Alarm Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber Optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B, Class A, and Supported Class X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2–27.6 VDC, 24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 \/ 38.4 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Multimode Transceiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMXVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Single-Mode Transceivers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMXLO2 \/ SMXHI2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMMXVR Fiber Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/125, 62.5\/125, or 100\/140 µm Multimode Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSMXLO2 \/ SMXHI2 Connector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplex SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMMXVR Connector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSMXLO2 Optical Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 dB Between Two Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSMXHI2 Optical Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 25 dB, Depending on Transceiver Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup Power Provision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal 24 VDC Input for Maintaining Network Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdapter Card and Electronics Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Panel Fiber-Optic Networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.8 lb (0.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e3X-FIB8\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe 3X-FIB8 is an EST3X network communication module specifically designed for compatible 3X-SFS fire alarm control systems. The assembly consists of an adapter card and electronics card that interface with the SFS1-CPU main board and accept separately ordered fiber-optic transceivers for network data transmission. It supports MMXVR multimode and SMXLO2\/SMXHI2 single-mode transceivers, allowing the fiber configuration to be selected according to network distance and cable requirements. Dedicated terminals accept an external 24 VDC backup source so network data transmission can remain active when the associated panel is powered down for service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eEight-Node Networking: Supports a fiber-optic network containing up to eight compatible EST3X control panels.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFiber-Optic Communication: Provides electrically isolated network communication suitable for distributed fire alarm installations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple Network Classes: Supports Class B, Class A, and supported Class X network arrangements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEST3X Compatibility: Designed specifically for compatible Edwards 3X-SFS \/ EST3X fire alarm control systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultimode Fiber Support: Compatible with MMXVR standard-output multimode fiber-optic transceivers.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSingle-Mode Fiber Support: Accepts SMXLO2 standard-output and SMXHI2 high-output single-mode transceivers.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModular Construction: Consists of an adapter card and dedicated fiber network electronics card.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBackup Power Connection: Provides terminals for an external 24 VDC backup source to maintain network communications during panel shutdown.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNetwork Data and Audio Support: Provides fiber-optic paths for compatible EST3X network data and audio communications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable Data Rates: Supports network communication rates of 19.2 or 38.4 kbps.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eService Indicators: Compatible transceivers incorporate transmit and receive activity LEDs for network diagnostics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible Fiber Selection: Supports different fiber types and optical budgets through the choice of separately installed transceiver modules.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 3X-FIB8 delivers the reliability and precision required for fiber-optic networking of distributed EST3X fire alarm and life-safety control panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52804583194922,"sku":"3X-FIB8","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1200_c6a8d495-7694-4d6f-afaa-28322e241ce9.jpg?v=1790791739","url":"https:\/\/iqelectro.com\/products\/edwards-est-3x-fib8-est3x-8-node-fiber-optic-fire-alarm-network-option-card","provider":"IQElectro","version":"1.0","type":"link"}