{"product_id":"edwards-est-bps6a-230-6-5a-220-240vac-remote-fire-alarm-booster-power-supply","title":"Edwards EST BPS6A\/230 6.5A 220-240VAC Remote Fire Alarm Booster Power Supply","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Edwards EST BPS6A\/230 is a 6.5 A remote booster power supply designed to expand supervised 24 VDC notification appliance power in fire alarm and life-safety systems. Edwards EST part number BPS6A\/230 operates from 220–240 VAC mains and provides four configurable NAC\/auxiliary outputs, battery charging and supervision, signal synchronization, and auxiliary power for compatible system equipment.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards EST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBPS6A\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBooster Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards BPS Series \/ Remote Booster Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised Remote Booster Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Total Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 A Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Output Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 A Maximum per Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour Class B or Two Class A Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Input Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC or 24 VDC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Auxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous, 3-3-3 Temporal, or Follow Host Panel NAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronization Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards Genesis and Enhanced Integrity Notification Appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V Batteries, Up to 10 Ah Each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Wire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 to 120 °F (0 to 49 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–93% RH, Noncondensing at 32 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor Steel Cabinet with Keyed Lockable Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, CSFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 13 lb (5.9 kg) Shipping Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eBPS6A\/230\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe BPS6A\/230 is part of the Edwards EST Remote Booster Power Supply family and is the 220–240 VAC version of the 6.5 A BPS platform. Its steel enclosure contains the power supply electronics, battery charging and supervision circuitry, configuration controls, option-module mounting provisions, and space for two standby batteries up to 10 Ah each. The unit accepts control inputs from compatible 12 or 24 VDC systems and can provide four Class B notification appliance circuits or two Class A circuits, with individual outputs configurable for NAC or auxiliary operation. Integrated Genesis and Enhanced Integrity synchronization, selectable temporal or continuous signaling, ground-fault supervision, battery monitoring, and trouble reporting support installation in fire alarm, emergency communication, security, and access-control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e6.5 A Output Capacity: Supplies up to 6.5 A total nominal 24 VDC output for notification and auxiliary loads.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFour Configurable Outputs: Provides four Class B NAC\/auxiliary circuits with a maximum rating of 3.0 A per circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClass A Capability: Four Class B circuits can be configured as two Class A notification appliance circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e220–240 VAC Input: Designed for 220–240 VAC, 50\/60 Hz mains operation with a 390 W input rating.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSignal Synchronization: Supports synchronization of compatible Edwards Genesis and Enhanced Integrity notification appliances.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable Signal Coding: Provides continuous, 3-3-3 temporal, or follow-input NAC signaling configurations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuxiliary Power Output: Includes a separate 24 VDC continuous auxiliary output rated up to 200 mA.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDual Control Inputs: Two sense inputs allow activation and supervision from compatible external control circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery Backup Support: Integrated charger and supervision circuitry accommodates two 12 V standby batteries, with up to 10 Ah batteries fitting inside the enclosure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGround-Fault Monitoring: Ground-fault detection can be enabled or disabled through an onboard configuration jumper.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTrouble Relay Output: Provides dedicated trouble relay contacts for communicating power supply fault conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpandable Installation: Internal mounting provisions support compatible interface or control modules without requiring a separate electronics enclosure.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe BPS6A\/230 delivers the reliability and precision required for expanding supervised notification appliance and auxiliary power in commercial fire alarm and life-safety systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52804550132010,"sku":"BPS6A\/230","price":545.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1200_86f5f834-916a-4a30-aa88-2d60e62affe8.jpg?v=1790790122","url":"https:\/\/iqelectro.com\/products\/edwards-est-bps6a-230-6-5a-220-240vac-remote-fire-alarm-booster-power-supply","provider":"IQElectro","version":"1.0","type":"link"}