{"product_id":"edwards-fsp1004r-fireshield-plus-conventional-fire-alarm-control-panel","title":"Edwards FSP1004R FireShield Plus Conventional Fire Alarm Control Panel","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Edwards FSP1004R FireShield Plus is a conventional fire alarm control panel configured with 10 Class B initiating device circuits and four Class B notification appliance circuits. Operating from a 120 VAC input, the panel provides a 24 VDC power supply for fire detection, notification, and auxiliary system loads. The FSP1004R supports configurable Class A circuit operation and expanded system power for commercial fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eEdwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eFSP1004R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eConventional Fire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eFireShield Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eConventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eZone Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e10 Class B or 5 Class A IDCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eNAC Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e4 Class B or 2 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eNAC Output per Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003ePrimary Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eInternal Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e24 VDC, 4.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eExpanded Power Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eUp to 7.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eSystem NAC\/Aux Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e3.5 A total; 7.0 A with F-XTR120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eBattery Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eUp to two 24 Ah sealed lead-acid batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eInternal Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003eUp to 18 Ah batteries fit within cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e3.75 × 15.00 × 30.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.2909%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.4898%;\"\u003e16 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eFSP1004R\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe FSP1004R is an Edwards FireShield Plus conventional fire alarm control panel designed for multi-zone fire detection and notification applications. Its circuit architecture supports 10 Class B or five Class A initiating device circuits, along with four Class B or two Class A notification appliance circuits. The panel operates from 120 VAC and incorporates a 24 VDC, 4.25 A power supply with support for increased capacity through the F-XTR120 transformer configuration. Battery standby capability accommodates up to two 24 Ah sealed lead-acid batteries, with batteries up to 18 Ah fitting within the control panel cabinet.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eConventional Fire Alarm Control: Provides centralized monitoring and notification for conventional initiating and signaling circuits.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eTen Initiating Circuits: Supports 10 Class B IDCs or five Class A IDCs for configurable detection zoning.\u003c\/li\u003e\n\u003cli\u003eFour Notification Circuits: Provides four Class B NACs or two Class A NACs for alarm signaling devices.\u003c\/li\u003e\n\u003cli\u003eNAC Output Capacity: Supports up to 2.0 A per notification appliance circuit within the panel's total available output.\u003c\/li\u003e\n\u003cli\u003eExpandable System Power: Provides 3.5 A total NAC\/auxiliary output, expandable to 7.0 A with an F-XTR120 transformer.\u003c\/li\u003e\n\u003cli\u003e120 VAC Operation: Designed for connection to a 120 VAC primary electrical supply.\u003c\/li\u003e\n\u003cli\u003eBattery Backup Support: Accommodates up to two 24 Ah sealed lead-acid standby batteries.\u003c\/li\u003e\n\u003cli\u003eIntegrated 24 VDC Supply: Provides a 4.25 A internal power supply with capacity expandable to 7.5 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FSP1004R delivers the reliability and precision required for conventional multi-zone fire detection, alarm notification, and life safety system control.\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52212305199402,"sku":"FSP1004R","price":827.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/Screen_Shot_2020-12-21_at_10.46.21_AM-removebg-preview-e1608567247502.png?v=1786395648","url":"https:\/\/iqelectro.com\/products\/edwards-fsp1004r-fireshield-plus-conventional-fire-alarm-control-panel","provider":"IQElectro","version":"1.0","type":"link"}