{"product_id":"edwards-nxds6i-nxds6i-dry-scroll-vacuum-pump-with-gas-ballast-and-integrated-electronic-controls","title":"Edwards NXDS6I nXDS6i Dry Scroll Vacuum Pump with Gas Ballast and Integrated Electronic Controls","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe Edwards NXDS6I is a dry scroll vacuum pump designed for clean evacuation in laboratory, analytical, and industrial systems. It provides a peak pumping speed of 6.2 m³\/h and an ultimate pressure of 0.020 mbar, supporting chamber evacuation and turbomolecular pump backing.\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"3\" height=\"356\" style=\"width: 84.3603%; height: 441.063px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eEdwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eVacuum Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eNXDS6I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eDry Scroll Vacuum Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eManufacturer Model \/ Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003enXDS6i \/ A73501983\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003ePump Technology and Variant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eDry scroll; standard version with gas ballast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eDisplacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e6.8 m³\/h (4.0 cfm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003ePeak Pumping Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e6.2 m³\/h (approximately 3.6 cfm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eUltimate Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e0.020 mbar (0.015 Torr), gas ballast closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eUltimate Pressure with Gas Ballast\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e0.050 mbar, gas ballast position 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eWater Vapor Handling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eMaximum inlet pressure: 35 mbar; maximum pumping rate: 110 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eInlet \/ Exhaust Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eDN 25 ISO-KF (NW25) \/ DN 25 ISO-KF (NW25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eNominal Rotational Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e1,800 rpm (30 rps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eSingle-phase, 100–127 \/ 200–240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eTypical Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e270 W at atmosphere; 260 W at ultimate pressure; 170 W in standby\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eCooling \/ Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eForced-air fan cooling; typical noise level 52 dB(A) at low fan speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e432 × 282 × 302 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eControl Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003eLocal buttons, parallel interface, and serial communication using Edwards DX protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.0239%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.7678%;\"\u003e26.2 kg (57.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eNXDS6I\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe NXDS6I is the standard nXDS6i model in the Edwards nXDS scroll pump series. Its hermetically sealed mechanism separates bearing lubrication from the vacuum environment. The integrated controller provides local start, stop, and standby functions alongside remote control capabilities. NW25 inlet and exhaust connections allow installation with compatible vacuum piping, filters, and accessories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDry Scroll Technology: Generates vacuum without oil sealing or lubrication in the pumping chamber.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHermetic Separation: Isolates bearing lubricant from process gases through a sealed bellows mechanism.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePumping Performance: Provides 6.2 m³\/h peak pumping speed and 6.8 m³\/h displacement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUltimate Vacuum: Reaches 0.020 mbar total pressure with the gas ballast closed.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Ballast Function: Supports water vapor pumping up to 110 g\/h under specified operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandby Control: Allows reduced-speed operation between pumping cycles.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemote Operation: Supports external control through parallel and serial interfaces.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard Vacuum Connections: Uses DN 25 ISO-KF inlet and exhaust flanges for compatible system connections.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe NXDS6I delivers the reliability and precision required for clean vacuum generation in analytical instruments, laboratory equipment, and turbomolecular backing systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52970930569514,"sku":"NXDS6I","price":10999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_f6e3081f-20e9-4b71-bbb4-13815aa258fd.webp?v=1792182967","url":"https:\/\/iqelectro.com\/products\/edwards-nxds6i-nxds6i-dry-scroll-vacuum-pump-with-gas-ballast-and-integrated-electronic-controls","provider":"IQElectro","version":"1.0","type":"link"}