{"product_id":"edwards-rzi16-2rs-remote-zone-interface-module-with-16-class-b-inputs","title":"Edwards RZI16-2RS Remote Zone Interface Module with 16 Class B Inputs","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eEdwards RZI16-2RS is an addressable Remote Zone Interface Module designed to connect conventional fire alarm devices to compatible Edwards\/Kidde intelligent fire alarm systems. It provides sixteen Class B initiating device circuits and two Class B supervised outputs, with rotary switches used for module addressing.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"428\" style=\"width: 89.0805%; height: 341.7px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eEdwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eRZI16-2RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eZone Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eRemote Zone Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9875px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eInput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003e16 Class B Initiating Device Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003e2 Class B Supervised Output Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eRotary Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eSLC Addresses Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003e18 consecutive addresses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eDIP switch selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2625px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eDefault Input Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eAlarm or Supervisory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.375px;\"\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eDefault Output Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eRelay or NAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eMounting bracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eConventional-to-addressable fire alarm integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eCompatible System Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003eEdwards\/Kidde FX Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eMaximum Alarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eMinimum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003e18.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6687%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.9231%;\"\u003e1.7 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About RZI16-2RS\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe RZI16-2RS is a remote zone interface module used within Edwards FX Series intelligent fire alarm installations. It bridges conventional initiating circuits with an addressable signaling line circuit, allowing existing conventional devices to operate within an intelligent system. The module uses rotary switches for address selection and DIP switches to configure default device types for the input and output circuits. It requires 18 consecutive SLC addresses and includes a mounting bracket for installation.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e16 Class B Inputs: Provides sixteen conventional Class B initiating device circuits.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e2 Supervised Outputs: Includes two Class B supervised output circuits configurable for supported applications.\u003c\/li\u003e\n\u003cli\u003eAddressable Interface: Connects conventional field devices to an intelligent fire alarm system through the SLC.\u003c\/li\u003e\n\u003cli\u003eRotary Addressing: Uses front-mounted rotary switches for device address selection.\u003c\/li\u003e\n\u003cli\u003eDIP Configuration: Two 8-position DIP switches configure default device types for the sixteen input circuits.\u003c\/li\u003e\n\u003cli\u003eOutput Configuration: A dedicated DIP switch selects the default relay or NAC output device type.\u003c\/li\u003e\n\u003cli\u003eMounting Bracket: Supplied with a mounting bracket for installation within the appropriate enclosure.\u003c\/li\u003e\n\u003cli\u003eFX Series Integration: Designed for use with compatible Edwards\/Kidde FX fire alarm control equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RZI16-2RS delivers the reliability and precision required for conventional device integration within addressable fire alarm systems.\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52464610017578,"sku":"RZI16-2RS","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/KC-RZI16-2RS.png?v=1788367004","url":"https:\/\/iqelectro.com\/products\/edwards-rzi16-2rs-remote-zone-interface-module-with-16-class-b-inputs","provider":"IQElectro","version":"1.0","type":"link"}