{"product_id":"edwards-signaling-116degex-fj-hazardous-strobe-ready-to-ship","title":"Edwards Signaling 116DEGEX-FJ Hazardous Location Xenon Strobe for Industrial Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"20\" data-end=\"498\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Edwards Signaling 116DEGEX-FJ is a hazardous location xenon strobe designed to provide high-intensity visual notification in classified industrial environments. Manufactured by Edwards Signaling, the 116DEGEX-FJ operates on 16–33 VDC or 16–33 VFWR and is engineered for dependable emergency signaling in facilities requiring explosion-proof visual alarms.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116DEGEX-FJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHazardous Location Strobe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrobe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXenon, Clear\/White Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLens Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Strobe Intensity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 cd (Ceiling), 60 cd (Wall)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16–33 VDC, 16–33 VFWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.505 A @ 24 VDC, 0.683 A @ 24 VFWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlash Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz (65 FPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePendant, Ceiling, Wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 150°F (-40°C to 66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Location Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I Div. 1 Groups C \u0026amp; D; Div. 2 Groups A, B, C \u0026amp; D; Class II Div. 1 Groups E, F \u0026amp; G; Div. 2 Groups F \u0026amp; G; Class III Div. 1 \u0026amp; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 3R, Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1971, ULC-S526-07, UL Listed, cUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADA Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1971 Listed for Hearing Impaired (Indoor, Non-Sleeping Areas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray Powder Coat Epoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronization Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM, BPS6A, BPS10A, APS6A, APS10A, iO64, iO500, Fireshield Plus, EST3X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 lb (8.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e116DEGEX-FJ\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 116DEGEX-FJ is part of the Edwards Signaling hazardous location visual notification product line developed for use in Class I, II, and III hazardous areas. It features a rugged gray powder-coated epoxy enclosure with a clear xenon strobe lens that provides reliable warning signals under demanding environmental conditions. The unit supports pendant, ceiling, and wall mounting while offering synchronization compatibility with a variety of Edwards fire alarm control modules and power supplies. Certified with UL, cUL, NEMA Type 3R, and Type 4X ratings, it is suitable for industrial facilities where hazardous location compliance and weather resistance are essential.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1341\" data-end=\"2149\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1163\" data-end=\"1902\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1885\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1126\" data-end=\"1911\"\u003e\n\u003cli data-section-id=\"1u79jqv\" data-start=\"1126\" data-end=\"1261\"\u003eHazardous Location Certified: Approved for Class I, II, and III hazardous locations with multiple division and group classifications.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"si50kx\" data-start=\"1262\" data-end=\"1360\"\u003eXenon Strobe Technology: Utilizes a clear xenon strobe to produce a high-visibility white flash.\u003c\/li\u003e\n\u003cli data-section-id=\"513izi\" data-start=\"1361\" data-end=\"1435\"\u003eWide Operating Voltage: Supports 16–33 VDC and 16–33 VFWR power sources.\u003c\/li\u003e\n\u003cli data-section-id=\"1yg6z1t\" data-start=\"1436\" data-end=\"1536\"\u003eHigh Light Output: Rated at 125 cd for ceiling mounting and 60 cd for wall mounting under UL 1971.\u003c\/li\u003e\n\u003cli data-section-id=\"15rhn41\" data-start=\"1537\" data-end=\"1644\"\u003eSynchronization Compatible: Works with compatible Edwards synchronization modules and fire alarm systems.\u003c\/li\u003e\n\u003cli data-section-id=\"98jx25\" data-start=\"1645\" data-end=\"1730\"\u003eFlexible Installation: Supports pendant, ceiling, and wall mounting configurations.\u003c\/li\u003e\n\u003cli data-section-id=\"l32mtx\" data-start=\"1731\" data-end=\"1829\"\u003eWeather-Resistant Enclosure: NEMA Type 3R and Type 4X rated for indoor and outdoor applications.\u003c\/li\u003e\n\u003cli data-section-id=\"qrkf89\" data-start=\"1830\" data-end=\"1911\"\u003eBroad Temperature Range: Operates reliably from -40°F to 150°F (-40°C to 66°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1913\" data-end=\"2093\"\u003eThe 116DEGEX-FJ delivers the reliability and precision required for hazardous location fire alarm notification, emergency warning, and industrial safety signaling applications.\u003c\/p\u003e","brand":"Edwards Signaling","offers":[{"title":"Default Title","offer_id":52026189316394,"sku":"116DEGEX-FJ","price":1459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_a6f3b7e5-120b-4c08-8a78-1d2993c5c47b.webp?v=1782922514","url":"https:\/\/iqelectro.com\/products\/edwards-signaling-116degex-fj-hazardous-strobe-ready-to-ship","provider":"IQElectro","version":"1.0","type":"link"}