{"product_id":"edwards-signaling-siga-rel-releasing-module-available-now","title":"Edwards Signaling SIGA-REL Analog Releasing Module for Signature Series Fire Suppression Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"464\" data-start=\"16\"\u003eThe Edwards Signaling SIGA-REL Analog Releasing Module is an intelligent addressable control module designed for fire suppression and releasing applications within Signature Series fire alarm systems. It provides reliable control of sprinkler, pre-action, deluge, and clean-agent suppression systems while integrating directly with compatible Edwards fire alarm control panels. The module supports advanced releasing functions with supervised circuits and configurable operational parameters.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 81.7029%; height: 505.051px;\" height=\"717\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eEdwards Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eSIGA-REL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eReleasing Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eSignature Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eAnalog Addressable Releasing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eSignature Data Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.8px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eRelease Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e2 Supervised Class B Release Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003ePre-Release Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e2 Supervised Class B NAC Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eManual Release Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e1 Supervised Class B Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eAbort Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e1 Supervised Class B Abort Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eRelay Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eForm C Relay Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e18.4 to 27.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eMaximum Release Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e2 A at 24 VDC per Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eEST2, EST3, QuickStart, Signature Series Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eSupported Suppression Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eSprinkler, Pre-Action, Deluge, CO₂, Halon, Foam, Clean Agent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003eEnclosure Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 31.8247%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9077%;\"\u003e0.52 lb (0.24 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSIGA-REL\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"526\" data-end=\"1232\"\u003eThe SIGA-REL is an addressable releasing module from the Edwards Signature Series that combines fire alarm detection and suppression control into a single networked platform. Designed for use with EST2, EST3, QuickStart, and compatible Signature loop controllers, it eliminates the need for a separate releasing panel in many applications. The module supports manual release, abort, and service disconnect functions while maintaining continuous supervision of connected circuits. Built-in programmable timers, configurable abort modes, and multiple supervised release outputs make it suitable for water-based and clean-agent fire suppression systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2143\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-spread=\"false\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1155\" data-end=\"1893\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1228\" data-end=\"2024\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1237\" data-end=\"1997\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1204\" data-end=\"1874\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1237\" data-end=\"2002\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1251\" data-end=\"1917\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1126\" data-end=\"1776\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1266\" data-end=\"1958\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1173\" data-end=\"1847\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1208\" data-end=\"1852\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1851\" data-start=\"1224\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1786\" data-start=\"1153\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1842\" data-start=\"1171\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1918\" data-start=\"1220\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1867\" data-start=\"1222\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1781\" data-start=\"1187\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1803\" data-start=\"1185\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1282\" data-end=\"2187\"\u003e\n\u003cli data-section-id=\"tlr716\" data-start=\"1282\" data-end=\"1410\"\u003eAddressable Architecture: Communicates directly with Signature Series loop controllers for intelligent system integration.\u003c\/li\u003e\n\u003cli data-section-id=\"1u8yjq7\" data-start=\"1411\" data-end=\"1523\"\u003eDual Release Circuits: Provides two supervised Class B release circuits for suppression system activation.\u003c\/li\u003e\n\u003cli data-section-id=\"1kceh2p\" data-start=\"1524\" data-end=\"1632\"\u003ePre-Release Notification Support: Includes two supervised pre-release notification appliance circuits.\u003c\/li\u003e\n\u003cli data-section-id=\"vlthj6\" data-start=\"1633\" data-end=\"1729\"\u003eManual Release Input: Supports dedicated manual release stations for emergency activation.\u003c\/li\u003e\n\u003cli data-section-id=\"jlhcyb\" data-start=\"1730\" data-end=\"1834\"\u003eAbort Functionality: Features a supervised abort input with multiple configurable operating modes.\u003c\/li\u003e\n\u003cli data-section-id=\"1s548n3\" data-start=\"1835\" data-end=\"1951\"\u003eBuilt-In Delay Timers: Adjustable manual, automatic, and abort delay settings enhance operational flexibility.\u003c\/li\u003e\n\u003cli data-section-id=\"ug5lle\" data-start=\"1952\" data-end=\"2076\"\u003eFire Suppression Compatibility: Suitable for sprinkler, deluge, pre-action, CO₂, Halon, foam, and clean-agent systems.\u003c\/li\u003e\n\u003cli data-section-id=\"16ncj9d\" data-start=\"2077\" data-end=\"2187\"\u003eForm C Relay Output: Includes a programmable relay for auxiliary control and room preparation functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2189\" data-end=\"2364\"\u003eThe SIGA-REL delivers the reliability and precision required for fire suppression release control and life safety system integration.\u003c\/p\u003e","brand":"Edwards Signaling","offers":[{"title":"Default Title","offer_id":51701456568618,"sku":"SIGA-REL","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/Edwards_SIGA-REL_540x_6bd72745-e7e6-435d-9c9f-0c39b2e0f0e1.jpg?v=1781269132","url":"https:\/\/iqelectro.com\/products\/edwards-signaling-siga-rel-releasing-module-available-now","provider":"IQElectro","version":"1.0","type":"link"}